Pressure ControlControl Board Diagnostics
1. Fig. 11. Remove five screws (307) and
cover (322).
2. Start sprayer.
3. TurnON/OFF switch ON.
4. Observe LED operation and reference following
table:
LED
BLINKS
SPRAYEROPERATION INDICATES WHATTO DO
Two times
repeatedly
Sprayer shuts down and LED contin-
ues to blink two times repeatedly
Run away pressure.
Pressure greater than
4500 psi (310 bar, 31
MPa).
1. Check pressure transducer con-
nection at control board
2. Replace pressure transducer
3. Replace control board
Three
timesre-
peatedly
Sprayer shuts down and LED contin-
ues to blink three times repeatedly
Pressure transducer is
faulty or missing
1. Check pressure transducer con-
nection at control board
2. Replace pressure transducer
3. Replace control board
Four times
repeatedly
Sprayer shuts down and LED contin-
ues to blink four times repeatedly
Generator voltage is
low
1. Increase engine throttle
2. Check wiring connections
3. Service Honda engine alternator
Five times
repeatedly
Sprayer shuts down and LED contin-
ues to blink five times repeatedly
High clutch current 1. Check clutch 5-pin bulkhead con-
nector. Clean contacts.
2. Measure 1.7 ±0.2Ωacross clutch
fieldat 70_F
3. Replace clutch field assembly
Six times
repeatedly
Sprayer shuts down and LED contin-
ues to blink six times repeatedly
High clutch temperature 1. If clutch is new, let sprayer cool
down and then restart
2. Inspect clutch. Replace clutch if
there is excessivewear.
3. Remove pump pin, separate pin-
ion housing from clutch housing.
Rotate rotor clockwise to check
for excessive drag.