Gun Operation Troubleshooting

Gun Operation Troubleshooting

Electric Shock Hazard

Installing and servicing this equipment requires access to parts which may cause an electric shock or other serious injury if the work is not performed prop- erly. Do not install or repair this equipment unless you are trained and qualified.

Pressurized Equipment Hazard

To reduce the risk of an injury, follow the Pressure Relief procedure on page 19 whenever you are instructed to relieve the pressure.

NOTE: Check all possible remedies in the Troubleshoot- ing Chart before disassembling the gun

.

Problem

Cause

Solution

 

 

 

Excessive spray fog.

Atomizing air pressure too high.

Close restrictor valve some, or

 

 

decrease air pressure as low as pos-

 

 

sible; minimum 40 psi (0.28 MPa, 2.8

 

 

bar) needed at gun for full voltage.

 

 

 

 

Fluid too thin.

Increase viscosity.

 

 

 

“Orange Peel” finish.

Atomizing air pressure too low.

Open atomizing air valve more or

 

 

increase gun air inlet pressure; use

 

 

lowest air pressure necessary.

 

 

 

 

Poorly mixed or filtered fluid.

Remix or refilter fluid.

 

 

 

 

Fluid too thick.

Reduce viscosity.

 

 

 

Fluid leaks from the fluid packing

Worn packings or rod.

Replace packings or rod; see page

area

 

30.

 

 

 

Air leaks from the front of the gun

Air valve (21) is not seating properly.

Clean and service air valve; see

 

 

page 34.

 

 

 

Fluid leakage from the front of the

Worn or damaged packing rod (26).

Replace; see page 30

gun

 

 

 

 

 

 

Worn fluid seat.

Replace fluid nozzle and/or needle;

 

 

see page 28.

 

 

 

 

Loose fluid nozzle (7).

Tighten; see page 28.

 

 

 

 

Damaged nozzle o-ring (7b).

Replace; see page 28.

 

 

 

Gun does not spray

Low fluid supply.

Add fluid if necessary.

 

 

 

 

Damaged air cap (9).

Replace; see page 28.

 

 

 

 

Dirty or clogged fluid nozzle (7).

Clean; see page 28.

 

 

 

 

Damaged fluid nozzle (7).

Replace; see page 28.

 

 

 

 

Damaged fluid adjustment valve (25).

Replace; see page 34.

 

 

 

Dirty air cap

Misaligned air cap (9) and fluid

Clean fluid buildup off air cap and

 

nozzle (7).

fluid nozzle seat; see page 28.

 

 

 

26