7.Set gun air regulator to deliver minimum 40 psi (0.28 MPa, 2.8 bar) at gun when triggered, for maximum transfer efficiency. See table at right.

Installation

10. Turn ES ON/OFF switch ON (I).

MAX FLUID

HI WPR: 100 PSI (7bar, 0.7 Mpa)

LO ES

MAX AIR

 

WPR:

100 PSI

 

(7bar,

0.7 Mpa)

I ES O

ti12732

 

TI1281A

 

 

Air Hose* Length

Regulator Setting**

ft (m)

psi (MPa, bar)

 

 

 

 

15 (4.6)

50 (0.35, 3.5)

 

 

25 (7.6)

60 (0.42, 4.2)

 

 

50 (15.3)

75 (0.52, 5.2)

 

 

*5/16 in. (8 mm) diameter/8 mm (5/16 in.) **Gun triggered

8.Spray test pattern. Check atomization. If over-atomi- zation occurs at minimum pressure, adjust restrictor valve. If atomization is inadequate, increase air pressure.

ti1282b

9.Adjust fan air adjustment valve: clockwise for a shorter pattern, counterclockwise for wider pattern.

11.Check that ES indicator or display is lit. If not, see Electrical Troubleshooting, page 22.

ES

ES

indicator

display

Standard Model

Smart Model

247936

247937

 

12.Spray test piece. Examine edges for coverage. If wrap is poor, see Spray Pattern Troubleshooting, page 25.

ti1285b

ti1283a

312900C

17

Page 17
Image 17
Graco Inc 247937, 247936, 312900C important safety instructions Turn ES ON/OFF switch on