Grounding

Read Fire and Explosion Hazard. See page 3.

1.Connect the ground wire clamp to a true earth ground.

TI10824A

2.Ground the object being sprayed, fluid supply con- tainer, and all other equipment in the spray area.

TI10832A

3.Ground all solvent pails. Use only metal pails. Do not place on a non-conductive surface such as paper or cardboard.

TI10835A

Flush

1.Relieve pressure. See Typical Installation, page 7.

2.Remove the air cap. Clean separately.

TI10834A

3. Place the suction tube in solvent.

TI10835A

Grounding

4.Turn off both air regulators.

--

TI10836A

5.Open the bleed-type air valve.

+TI10827A

6.Open the pump air regulator until the pump starts.

+

TI10836A

7.When clean solvent flows without air from the gun stop spraying.

TI10870A

8.Remove the suction tube from the solvent. Continue to spray until all solvent is out of the gun.

 

 

 

 

 

 

 

 

 

TI10835A

 

 

 

 

TI10870A

 

 

 

 

9. Close the bleed type air valve.

TI10826A

-

10. Relieve pressure. See Typical Installation, page 7.

312473B

9