Grounding
Read Fire and Explosion Hazard. See page 3.
1.Connect the ground wire clamp to a true earth ground.
TI10824A
2.Ground the object being sprayed, fluid supply con- tainer, and all other equipment in the spray area.
TI10832A
3.Ground all solvent pails. Use only metal pails. Do not place on a
TI10835A
Flush
1.Relieve pressure. See Typical Installation, page 7.
2.Remove the air cap. Clean separately.
TI10834A
3. Place the suction tube in solvent.
TI10835A
Grounding
4.Turn off both air regulators.
--
TI10836A
5.Open the
+TI10827A
6.Open the pump air regulator until the pump starts.
+
TI10836A
7.When clean solvent flows without air from the gun stop spraying.
TI10870A
8.Remove the suction tube from the solvent. Continue to spray until all solvent is out of the gun.
|
|
|
|
|
|
|
|
|
TI10835A |
|
|
|
| TI10870A | |||
|
|
|
|
9. Close the bleed type air valve.
TI10826A
-
10. Relieve pressure. See Typical Installation, page 7.
312473B | 9 |