Setup

Connect Hoses and Mount Pump

Connect hoses and pump as follows:

NOTE: This pump is supplied with a bracket (D) which holds it to the side of a drum. If you want to install the pump on a wall, do not install the hanging bracket. Use Graco Wall Mounting Bracket 206–778 or equivalent for wall setup.

1.Screw the hose stud (A) of the suction hose (B) into the pump’s intake housing (C) using LoctiteR Pipe Sealant. Assemble the hanging bracket (D) to the pump with the screw, lockwasher, and nut (E) provided.

2.Remove the ball valve (17, see Parts) from Model 205–985. It is not used in this setup. Hang the pump on your empty cleaning solution drum.

NOTE: A pump runaway valve (F) may be installed near the pump air inlet. This valve senses when the pump is running too fast and shuts off the air to the pump.

3.Connect the air line lubricator (G) to the pump air inlet using pipe sealant. Install a pump air bleed valve (H) and air regulator and gauge (J) to the air line lubricator. Connect an air line filter (K) to the regulator. From the air line filter, install an air drain valve (L), bleed–type air valve (M), and connect to the air supply using electrical conductive air supply hose (N).

4.Close to the pump’s 1/2 npt(f) fluid outlet, install a tee (P) and a fluid drain valve (R). Then install a fluid hose (S) and Hydra–Clean gun (T). The hose and gun are supplied with Model 205–985, but must be purchased separately for Model 207–860.

CAUTION

Oils containing phosphate ester or chlorinated hydro- carbons are not compatible with the plastic bowl of the lubricator – be sure that oil used to lubricate the compressor is free of these additives.

63￿6￿993

Page 6
Image 6
Graco Inc 306-993, 207-860, 205-985 warranty Connect Hoses and Mount Pump