Graco Inc 307741, 237000, 235525, 220106, 03695A manual Installation, General Information Grounding

Models: 235525 237000 03695A 220106 307741

1 28
Download 28 pages 26.16 Kb
Page 5
Image 5

Installation

General Information

NOTE: Reference numbers and letters in parentheses in the text refer to the callouts in the figures and the parts drawing.

NOTE: Always use Genuine Graco Parts and Acces- sories, available from your Graco distributor.

Grounding

WARNING

FIRE AND EXPLOSION HAZARD Before operating the pump, ground the system as explained below. Also read the section FIRE AND EXPLOSION HAZARD on page 4.

1.Pump: Use a ground wire and clamp as shown in Fig. 1. Loosen the grounding lug locknut (W) and washer (X). Insert one end of a 12 ga (1.5 mm@) minimum ground wire (Y) into the slot in lug (Z) and tighten the locknut securely. Connect the other end of the wire to a true earth ground. Order part number 237569 Grounding Clamp and Wire.

2.Air and fluid hoses: Use only electrically conduc- tive hoses.

3.Air compressor: Follow manufacturer’s recommen- dations.

4.Spray gun or dispensing valve: Ground through connection to a properly grounded fluid hose and pump.

5.Object being sprayed: Follow your local code.

6.Fluid supply container: Follow your local code.

7.Solvent pails used when flushing: Follow your local code. Use only metal pails, which are conductive, placed on a grounded surface. Do not place the pail on a nonconductive surface, such as paper or cardboard, which interrupts the grounding continu- ity.

8.To maintain grounding continuity when flushing or relieving pressure, hold a metal part of the spray gun/dispense valve firmly to the side of a grounded metal pail, then trigger the gun/valve.

Z

X

WY

Fig. 1

307741 5

Page 5
Image 5
Graco Inc 307741, 237000, 235525, 220106, 03695A manual Installation, General Information Grounding