Graco Inc ti14916a, 3A0243A important safety instructions Pressure Control, Pump ON/OFF Switch

Models: 3A0243A ti14916a

1 32
Download 32 pages 52.77 Kb
Page 21
Image 21

Pressure Control

Pressure Control

Pump ON/OFF Switch

Removal

1.Remove two screws (71) and swing down cover (130a).

2.Disconnect pump ON/OFF switch (130f) connector from control board.

3.Press in on two retaining tabs on each side of pump ON/OFF switch (130f) and remove switch from cover.

Installation

1.Install new pump ON/OFF switch (130f) so tabs of switch snap into place on inside of cover.

2.Connect pump ON/OFF switch connector to control board.

3.Swing up cover (130a) and secure with two screws (71).

TO ENGINE 15 5900/7900

130a

130f

130j

 

 

 

 

130d

71

130h

113

 

 

GROUND 129

 

3900

CLUTCH (-)

130a

CLUTCH (+)

 

 

130r

130c

123

 

130f

130g

CLUTCH

39 GALLON COUNTER

130b

66

130d

130e

72

66

67

ti14915a

3A0243A

21

Page 21