SERVICE

TROUBLESHOOTING

PROBLEM

Low Pressure

Worn nozzle.

 

Belt slippage.

 

Air leak in inlet plumbing.

 

Relief valve stuck, partially

 

plugged or improperly

 

adjusted; valve seat worn.

 

Tank outlet filter clogged.

 

Worn packing. Abrasives in

 

pumped fluid or severe cavita-

 

tion.Inadequate water supply.

IFouled or dirty inlet or discharge

1

valves.

Worn inlet or discharge valve.

 

Leaky discharge hose.

 

Restricted inlet or air entering

 

the inlet plumbing.

 

Inlet restrictions and/or air

 

leaks. Stuck inlet or discharge

 

valve.

 

Leaking high pressure seals.

Water leabge.from under

Worn packing

manifold.

 

Water in pump crankcase.

May be caused byhumid air

the-"condensing into water inside the crankcase.

Replace with nozzle of proper size.

Xghten or replace; use correct belts andreplan all three at the same time.

Disassemble, reseal, and reassemble.

Clean, and adjust relief valve; check for worn and dirty valve seats. Kit available.

Clean. Check more frequently.

Install proper filter. Check flow available to

pump.

Clean inlet and dischargevalve assemblies

Replace worn valves, valve seats and/or discharge hose.

Proper size inlet plumbing; check for air tight

seal.

Clean out foreign material, replace worn valves.

Replace seals

Install new packing

Change oil at 3rnonthor500Hour intervalsusing Crankcase Oil (other approved oil every monthor

200hours1 P/N 801-144.

Strong surging at the inlet and owl pressure on the discharge side.

Electric motor stops while Ispraying.

Electric motor labors when starting; blows fuses.

Scored plungers.

Over pressure to inlet manifold. Damaged or worn plungers.

Abrasive material in the fluid being pumped.

Excessive pressure and/or temperature of fluid being pumped.

Over pressure of pumps.

Running pump dry.

Foreign particles in the inlet or discharge valve, or worn inlet and/or discharge valves.

Building circuit fuse blown. Overload switch has opened.

Building circuit fuse blown.

Overload switch has opened.

Tip plugged.

Not wired properly,

Replace plungers.

Reduce inlet pressure.

Replace plungers.

Install proper filtration on pump inlet plumbing.

Check pressures and fluid inlet temperature; be sure they are within specified range. Pump will overheat if run for over 10 minutes without spraying.

Check tip size. Use only proper tip. Do not run Dum0 without water.

Check forsmooth lap surfaces oninlet and . discharge valve seats. Discharge valve seats and inlet valve.seats may be lappedon a veryfine 011 stone.

Check, replace or reset.

Shut unit off, hold gun open, restart.

:heck, replace or reset.

Shut unit off, relieve. , pressure-allow :ocool.

qemove and clean.

3eplace capacitor.

See wiring diagram.

12801-765

Page 12
Image 12
Graco Inc 800-076, 801-765, 1020E manual Service, Troubleshooting Problem