Graco Inc 800-909, 740, 800-906, 800-907 Troubleshooting Chart, 385349, Problem, Cause, Solution

Models: 1040 1035 735 308-534 800-908 800-907 800-906 740 800-909

1 20
Download 20 pages 49.05 Kb
Page 9
Image 9
TROUBLESHOOTING CHART

TROUBLESHOOTING CHART

WARNING

To reduce the risk of serious bodily injury, including fluid injection, splashing in the eyes or on the skin, or injury from moving parts, always follow the Pressure Relief Procedure Warning before proceeding.

PROBLEM

CAUSE

SOLUTION

Low pressure and/or

Worn or wrong size tip.

Replace with tip of proper size.

pump runs rough

Inlet filter clogged.

Clean. Check more frequently.

 

 

Worn packings, abrasives in water or

Check filter. Replace packings. See PUMP SERVICE.

 

natural wear.

 

 

Inadequate water supply.

Check water flow rate to pump. Unit must have a

 

 

minimum 55 gallon float valve controlled water holding

 

 

tank.

 

Belt slippage.

Tighten or replace.

 

Fouled or dirty inlet or discharge valves.

Clean inlet and discharge valve assemblies. Check

 

Even a small particle can cause the valve

filter.

 

to stick.

 

 

Restricted inlet.

Check garden hose, may be collapsed or kinked.

 

Worn inlet or discharge valves.

Replace worn valves.

 

Leaking high pressure hose.

Replace high pressure hose.

Water leakage from

Worn packings.

Install new packings. See PUMP SERVICE.

under pump manifold

 

 

Water in pump

Humid air condensing inside crankcase.

Change oil as specified in MAINTENANCE.

 

Worn packings.

Install new packings. See PUMP SERVICE.

 

Oil seals leaking.

Install new oil seals. See PUMP SERVICE.

 

 

 

Frequent or

Scored, damaged or worn plungers.

Install new plungers. See PUMP SERVICE.

premature failure of

Abrasive material in the fluid being pumped.

Install proper filtration on pump inlet plumbing.

the packings

Inlet water temperature too high.

Check water temperature; may not exceed 160_F.

 

 

Overpressurizing pump.

Do not modify any factory–set adjustments. See

 

 

EQUIPMENT MISUSE HAZARD.

 

Excessive pressure due to partially plugged

Clean or replace tip. See Installing and Changing Spray

 

or damaged tip.

Tips.

 

Pump running too long without spraying.

Never run pump more than 10 minutes without

 

 

spraying.

 

Running pump dry.

Do not run pump without water.

Strong surging at the

Foreign particles in the inlet or discharge

Clean or replace valves. See PUMP SERVICE.

inlet and low pressure

valve or worn inlet and/or discharge

 

on the discharge side

valves.

 

Unit will not start

Unit not plugged in.

Check power cord.

 

Electrical service off/GFCI activated.

Check fuse/circuit breaker. Check for proper grounding.

 

Thermal overload has tripped.

Press reset button on motor for 1 phase units. Press

 

 

stop button on the motor starter for 3 phase units.

 

 

 

3￿8￿534￿9

Page 9
Image 9
Graco Inc 800-909, 740, 800-906, 800-907, 800-908, 308-534, 735, 1035 Troubleshooting Chart, 385349, Problem, Cause, Solution