INSTALLATION
PUMP OIL
LEVEL
INDICATOR
WINDOW
HIGH |
|
PRESSURE |
|
HOSE | PUMP DIP- |
CONNECTION | |
2 x 1/2” NPT(f) | STICK |
WATER |
|
CONNECTION |
|
2 x 1” NPT(f) |
|
Water supply tank, gun & wand assem- bly, hose assembly and motor starter are not included.
Figure 1
Check for Shipping Damage
Check the unit for any damage that may have occurred in shipping. Notify the carrier immediately if there is any damage.
Install the appropriate spray tip on the wand. See Installing and Changing Spray T ips. If you are using a sandblaster kit, see its separate manual for installation instructions.
Set Up
Before connecting the unit, be sure the electrical service matches the specification in Technical Data (inside back cover) and the voltage label on the unit. With the unit off, connect the power supply cord to a grounded,
If you are using a downstream chemical injector, install it between the pump unloader and the high pressure hose.
Connect the high pressure hose between the pump outlet and the gun inlet.
CAUTION
Up to 100 ft (30 m) of high pressure hose may be used. Longer hoses may af fect sprayer performance, and chemical injector performance, if used.
Connect to Water Supply
CAUTION
Before attaching to the water supply, check your local plumbing code regarding
A backflow preventer P/N
Install a regulating water valve, P/N
Do not exceed 160 _ F (70 _ C) inlet water temperature.
NOTE: The water source for the unit must have a minimum 100 gallon float valve controlled water holding tank.
385345