WARNING

HIGH PRESSURE SPRAY CAN CAUSE SERIOUS INJURY. FOR PROFESSIONAL USE ONLY. OBSERVE ALL WARNINGS.

Read and understand all instruction manuals before operating equipment.

FLUID INJECTION HAZARD

General Safety

This pressure washer generates very high fluid pressure. Spray from the gun, leaks or ruptured components can inject fluid through your skin and into your body and cause extremely serious bodily injury including the need for amputation. Also, fluid injected or splashed into the eyes or on the skin can cause serious damage.

NEVER point the spray gun or wand at anyone or at any part of the body . NEVER put hand or fingers over the spray tip.

ALWAYS follow the Pressure Relief Procedure, before cleaning or servicing any part of the sprayer.

NEVER try to stop or deflect leaks with your hand or body.

Be sure equipment safety devices are operating properly before each use.

Medical Treatment

If any fluid appears to penetrate your skin, get

EMERGENCY MEDICAL TREATMENT AT ONCE. DO NOT TREAT AS A SIMPLE CUT. Tell the doctor exactly what fluid was injected.

NOTE TO PHYSICIAN: Injection in the skin is a traumatic injury. It is important to treat the injury surgically as soon as possible. Do not delay treatment to research toxicity. Toxicity is a concern with some exotic coatings injected directly into the bloodstream. Consultation with a plastic surgeon or reconstructive hand surgeon may be advisable.

Pressure Relief Procedure

To reduce the risk of serious bodily injury, including fluid injection and splashing in the eyes or on the skin, always follow this procedure whenever you stop spraying for more than 10 minutes, when shutting down, and before checking or repairing any part of the system.

1.Engage the trigger safety latch.

2.Turn the sprayer off.

3.Disconnect the electrical supply.

4.Shut off the water supply.

5.Disengage the trigger safety latch and trigger the gun to relieve pressure, and then engage the trigger safety latch again.

6.Before long–term (overnight) storage, disconnect the water supply and disconnect the electricity.

Spray Gun Safety Devices

Be sure all gun safety devices are operating properly before each use. Do not remove or modify any part of the gun; this can cause a malfunction and result in serious bodily injury.

SAFETY LA TCH: Whenever you stop spraying for a moment, always set the gun safety latch in the engaged or “safe” position, making the gun inoperative. Failure to properly set the safety latch can result in accidental triggering of the gun.

SPRAY TIP SAFETY: Use extreme caution when cleaning or changing spray tips. If a spray tip clogs while

spraying, engage the gun safety latch immediately. ALWAYS follow the Pressure Relief Procedure and then remove the spray tip to clean it.



Page 2
Image 2
Graco Inc 800-906, 800-909, 740, 735 General Safety, Medical Treatment, Pressure Relief Procedure, Spray Gun Safety Devices

1040, 1035, 735, 308-534, 800-908 specifications

Graco Inc is a renowned company specializing in fluid handling systems and equipment. Among their extensive product line, the model numbers 800-908, 308-534, 1040, 800-906, and 800-909 stand out, reflecting the company's commitment to quality and innovation in fluid management technologies.

The Graco 800-908 is a versatile air-operated diaphragm pump designed for transferring fluids and handling higher viscosity materials. One of its main features includes a corrosion-resistant construction that allows it to handle a variety of liquids, including corrosive and abrasive materials. This pump is equipped with a robust motor that ensures reliable performance in various industrial applications, making it an excellent choice for contractors and manufacturers alike.

The model 308-534 is known for its efficiency and compact design. Designed for use in low-pressure applications, it is suitable for transferring a range of non-viscous fluids. The unique features of this model include a lightweight design and easy installation, which are especially beneficial in tight spaces. Its maintenance-free operation further enhances its appeal for users looking for reliability and cost-effectiveness.

The Graco 1040 is a portable electric pump specifically designed for transferring lightweight materials, such as paints and coatings. This model features an adjustable flow rate, allowing users to control the output based on their specific needs. Its ergonomic design minimizes user fatigue, and the inclusion of built-in safety features ensures a secure operation, making it ideal for both commercial and residential applications.

The 800-906 model is a versatile transfer pump that excels in high-flow applications. Its dual-stage design allows for superior performance when dealing with thicker fluids, ensuring that users can quickly and efficiently transfer materials. This model is engineered for durability, featuring heavy-duty construction that withstands the rigors of industrial environments.

Lastly, the Graco 800-909 stands out as a powerful solution for high-volume fluid transfer tasks. It is designed for use in industries requiring rapid and reliable material movement, such as automotive and manufacturing. This pump is equipped with advanced technology that optimizes energy consumption while enhancing flow rates, thus providing an environmentally friendly option that does not compromise on performance.

In summary, Graco Inc's models 800-908, 308-534, 1040, 800-906, and 800-909 each exhibit unique features catering to diverse fluid handling needs, showcasing the company's dedication to innovation, efficiency, and reliability in fluid management solutions.