MAINTENANCE | ||
|
|
|
WARNING
ELECTRIC ShOCK can kill.
•Have an electrician install and service this equipment.
•Turn the input power off at the fuse box before working on equipment.
•Do not touch electrically hot parts.
•Prior to Performing preventative main- tenance, perform the following capaci- tor discharge procedure to avoid elec- tric shock.
INPuT FILTER CAPACITOR
DISChARGE PROCEDuRE
1.Turn off input power or disconnect input power lines.
2.Remove the 5/16" hex head screws from the side and top of the machine and remove
3.Be careful not to make contact with the capacitor terminals that are located in the top and bottom of the Power Board.
4.Obtain a high resistance and high wattage resistor
5.Locate the four capacitor terminals (large hex head cap screws) shown in Figure D.1. One pair at the top and one pair at the bottom of the Power Board.
6.Use electrically insulated gloves and insulated pli- ers. Hold body of the resistor and connect resistor leads across the two capacitor terminals. Hold resistor in place for 10 seconds. DO NOT TOUCH CAPACITOR TERMINALS WITH YOUR BARE HANDS.
7.Repeat discharge procedure for the capacitor on other two terminals.
8.Check voltage across terminals of all capacitors with a DC voltmeter. Polarity of capacitor terminals is marked on PC board above terminals. Voltage should be zero. If any voltage remains, repeat this capacitor discharge procedure.
FIGuRE D.1 — LOCATION OF INPuT FILTER CAPACITOR TERMINALS.
POWER | UPPER |
BOARD | CAPACITOR TERMINALS |
LOWER
CAPACITOR
TERMINALS
POWER
RESISTOR
RIGHT SIDE OF MACHINE | INSULATED |
| PLIERS |
INSULATED
GLOVES
ES 275i