E-6

 

TROubLEShOOTING

E-6

 

 

 

 

 

 

Observe all Safety Guidelines detailed throughout this manual

 

 

 

 

 

 

PRObLEMS

POSSIbLE

RECOMMENDED

 

 

(SYMPTOMS)

CAuSE

COuRSE OF ACTION

 

 

 

 

 

 

OuTPuT PRObLEMS

The machine will not produce more than 200 amps.

1. This may be normal operation. If

 

the output current exceeds 300

 

amps, an electronic protection

 

circuit will reduce the current to

 

less than 200 amps. The machine

 

will continue to produce this low

 

current until the protection circuit

If all recommended possible areas of

is reset. Reset occurs when the

output load is removed.

misadjustment have been checked

and the problem persists, Contact

 

2. Check the input voltage and input

your local Authorized Field Service

Facility.

voltage reconnect procedures.

 

See Input Voltage Reconnect

 

Procedure.

 

3. Check for loose or faulty welding

 

cables.

 

 

 

CAuTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, con- tact your local authorized field service facility for technical troubleshooting assistance before you proceed.