A-1

 

 

 

INSTALLATION

 

 

 

 

A-1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Technical Specifications - ES 275i

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INPuT AT RATED OuTPuT - ThREE PhASE ONLY

 

 

 

 

INPuT VOLTS-hz

OuTPuT

 

INPuT

Idle

 

 

 

Efficiency

 

 

 

 

 

CONDITIONS

CuRRENT

Power

 

 

@ Rated Output

 

 

 

 

 

 

 

 

AMPS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

200A@28V.100%

27/25/13/11

 

 

 

 

 

 

 

208/230/460/575V - 60Hz.

250A@30V. 60%

34/33/17/14

 

 

 

 

 

 

 

 

 

 

275A@31V. 35%

38/37/19/16

150W Max

 

 

87%

 

220/380/400/415/440 - 50Hz

200A@28V.100%

25/15/15/14/13

 

 

 

 

 

 

250A@30V. 35%

32/20/19/18/17

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INPuT AT RATED OuTPuT -

SINGLE PhASE

ONLY

 

 

 

 

INPuT VOLTS-hz

OuTPuT

 

INPuT

Idle

 

 

 

Efficiency

 

 

 

 

 

CONDITIONS

CuRRENT

Power

 

 

@ Rated Output

 

 

 

 

 

 

 

 

AMPS

 

 

 

 

 

 

 

 

 

 

200A@28V.100%

55/48/26/21

 

 

 

 

 

 

 

208/230/460/575V - 60Hz.

250A@30V. 60%

72/62/33/27

 

 

 

 

 

 

 

 

 

 

275A@31V.* 35%

80/70/38/31

150W Max

 

 

87%

 

 

220/380/400/415/440 - 50Hz

200A@28V.100%

48/32/30/29/27

 

 

 

 

 

 

 

250A@30V. 35%

63/42/40/38/36

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OuTPuT (ThREE AND SINGLE PhASE)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WELDING

 

 

 

 

NO LOAD 

 

 

 

 

 

CuRRENT RANGE

 

 

 

VOLTAGE

 

 

 

 

 

5-275 Amps

 

 

 

 

70 VDC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RECOMMENDED MINIMuM INPuT WIRE AND FuSE SIzES

 

 

 

 

 

ThREE PhASE

 

 

 

 

SINGLE PhASE

 

Input Voltage-hz

Cord Size AWG(mm2)

Fuse Size

Input Voltage-hz

Cord Size AWG(mm2)

 

Fuse Size

 

 

 

based on a type S, SJ, SJO

(Time Delay Fuse)

 

 

based on a type S, SJ, SJO

(Time Delay Fuse)

 

 

 

or SJT Flexible cord

Amps

 

 

or SJT Flexible cord

 

Amps

 

 

 

in 30°C Ambient

 

 

 

 

in 30°C Ambient

 

 

208/230-60

8(8.4)

 

60

 

 

208-60

 

4 (25)1

 

 

 

100

460/575-60

14(2.5)

 

35

 

 

230-60

 

6(16)1

 

 

 

100

 

 

 

 

 

 

 

460/575-60

 

10 (6)

 

 

 

60

220-50

8(8.4)

 

60

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100

380/400/415-50

12(4)

 

35

 

 

220-50

 

6(16)1

 

 

 

440-50

14(2.5)

 

35

 

380/400/415-50

 

8(10)

 

 

 

60

 

 

 

 

 

 

 

 

440-50

 

10(6)

 

 

 

60

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PhYSICAL DIMENSIONS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

height

 

Width

 

Depth

 

 

Weight (With Cord)

13.6in.(345mm) - Handle Folded Down

 

 

 

20.25 in.(514mm)

 

 

 

 

 

 

 

 

 

 

9.0 in.(229mm)

 

 

 

 

 

 

54.5lbs. (24.7Kg)

16in.(406mm) - Handle Up

 

 

 

21.7 in.(551)-With Cord Strain Relief

 

 

 

TEMPERATuRE RANGES

OPERATING TEMPERATuRE RANGE

-20°C to +40°C

STORAGE TEMPERATuRE RANGE

-40°C to +40°C

(1) When operating on these inputs, the line cord may need to be changed

* On 208VAC single phase the 35% duty cycle output rating is 275A @ 29V.

ES 275i

Page 8
Image 8
Lincoln Electric ES 275I specifications Technical Specifications ES, ThREE PhASE Single PhASE