Graco Inc EM390 Replacing the Pressure Control & Circuit Board, Circuit Board Removal

Models: EM390

1 38
Download 38 pages 40.64 Kb
Page 23
Image 23

REPLACING THE PRESSURE CONTROL & CIRCUIT BOARD

WARNING

To reduce the risk of serious bodily injury, including fluid injection or splashing in the eyes or on the skin, or injury from moving parts, always follow the Pressure Relief Procedure Warning on page 16 before checking, adjusting, cleaning or shutting off the sprayer. Unplug the power supply cord.

23

13

MOTOR

1

 

LEADS

 

BLACK

 

GREEN & YELLOW

 

RED

 

PINK

 

BROWN

NOTE: A circuit board (23f) is not included with a new

 

 

 

 

pressure control (50). However, it is included with

TRIAC

 

303

 

a new motor and it can be ordered separately.

LEADS

 

23c

 

 

 

 

Be sure to order the correct circuit board. See the

WHITE

 

23f

 

 

 

 

 

application information on page 26.

RED

 

 

 

 

 

 

 

CAUTION

WHITE

 

 

 

 

 

 

 

Do not allow the fittings (A) to move when removing

 

 

 

 

the elbow (312) or nipple (313) from the pressure

 

 

GREEN

 

control, to avoid altering the factory setting of the

 

 

BLACK

 

pressure control or damaging the pressure control.

 

 

 

 

 

WHITE

 

 

 

 

 

 

 

 

POWER

Circuit Board Removal

50

 

SUPPLY

41

LEADS

1.

Remove the pressure control cover (41). Pull the cir-

Fig 23±1

0749

 

cuit board (23f) out carefully, just enough to reach the

 

 

 

 

 

 

wire terminals. Disconnect the leads. Remove the

 

 

 

 

board. See Fig 23±1.

 

 

 

Pressure Control Removal

 

 

40

 

 

50

2. Disconnect the hose (52). See Fig 23±2.

 

 

 

 

 

3. Disconnect the remaining two motor leads (black and

A

 

41

312

 

 

 

green/yellow). See Fig 23±1.

 

 

 

4. Remove the screws (7). See Fig 23±2.

 

 

 

5. Pull the pressure control (50) away from the conduit

 

 

313

 

 

 

 

(1) and carefully guide the leads through the connec-

47

 

 

 

tor (303) one at a time. See Fig 23±1.

 

 

302

6.

Remove the mounting bracket (40). Remove the fit-

52

 

7

 

tings (302, 312, and 313). Remove the fluid filter (47).

 

 

 

Fig 23±2

 

0677

 

 

 

 

 

Install these parts on the new pressure control. See

 

 

 

 

Fig 23±2.

10. Mount the pressure control on the cart.

Pressure Control Installation

11. ADJUST THE PRESSURE CONTROL! See page 24.

 

 

 

7.

Guide the motor leads into the new pressure control.

 

 

 

8.Position the circuit board in the pressure control so the wire connectors are at the top. Connect the leads to the board. Guide the leads into the pressure con- trol, making sure they don't catch on anything. Slide the board into place.

9.Connect any other loose wires. See Fig 23±1.

WARNING

Adjust the pressure control whenever a new or used pressure control or circuit board is installed, to reduce the risk of overpressurization which can result in component rupture, fire or explosion. Im- proper adjustment may also prevent the sprayer from obtaining the maximum working pressure, re- sulting in poor sprayer performance.

307-724 23

Page 23
Image 23
Graco Inc EM390 Replacing the Pressure Control & Circuit Board, Circuit Board Removal, Pressure Control Removal