Unit Installation

Unit Installation

IMPORTANT:This brewer should be installed by a knowledgeable and experienced commercial equipment installer.

Brewer Contents

Your brewer package should include the following: 1 Grinderbrewer (either single or dual bean)

1 Operation and Instruction Manual (this manual)

1 Hose to 1/4" flare fitting (part # 61237)

Tools Required for Installation

#2 Phillips screwdriver 9/16" wrench

5/8" wrench

(or crescent wrench) 6" level

NOTE: Other tools may be needed depending on the type of water supply tubing and location.

1.Inspect unit to see if any damage occurred in shipment.

2.Position brewer on counter. Place on sturdy permanent counter top. If you have an airpot brewer, install the 4" plastic legs (included) at the bottom of the brewer. Lean the brewer towards its side to expose screwholes under- neath for legs. Adjust the leg height to suit the size of airpots you will use. IMPORTANT: Adjust the feet to level the brewer. With bubble level, check to see that the brewer is level on countertop.

Water Hook-up (All Models) (Refer to Figure A)

IMPORTANT: This equipment must be installed in compliance with applicable Federal, State and/or Local plumbing codes having jurisdiction. Incoming water pressure should be greater than 20 psi and not more than 100 psi.

1.The incoming water supply should have a shut-off valve connected in-line. The end should have a female 1/4" flare fitting. Water supply should be a 1/4" I.D. dedicated line branched off a 1" or larger supply line.

2.Prior to installing the brewer, flush out the water line by running approximately 1 gal. of water into a pail. This will insure no sediment from a new installation can get in the brewer.

3.Make sure your source water is turned off. Connect the water line’s 1/4" female flare fitting (1) to the 1/4" male fit- ting on the hose connector (2).

4.Make sure Grind’n Brew is unplugged. Connect the water line to the brewer with the hose connector (2).

5.Turn the water valve on, sending water to the brewer. If there are any leaks, tighten connections to stop leakage.

Figure A