American Metal Ware Hot Water Boiler
IV) Trouble Shooting Auto Refill, Low Water Cutoff, and Dual Level Control System (continued)
PROBLEM | POSSIBLE CAUSE | SERVICE CHECK | REMEDY | ||
|
|
|
|
| |
C) Auto refill fails to | 3) | Water strainer clogged. | Water pressure before | Remove and clean micromesh screen | |
fill water tank |
|
| strainer and not after. | filter located in water strainer. | |
(continued). |
|
|
|
| |
4) | No power on Dual | Check for 120V AC across | If voltage missing or incorrect, | ||
| |||||
|
| Level Control. | “H” and “N” terminals. | check wiring for looseness, breaks, | |
|
|
|
| and proper connections. | |
|
|
|
|
| |
| 5) | Fill solenoid valve | Disassemble. | Clean out and/or replace plunger | |
|
| clogged with scale |
| assembly or entire valve. May require | |
|
| or frozen closed. |
| new coil. Caution is advised to avoid | |
|
|
|
| damage to valve. See valve instruction | |
|
|
|
| sheet. | |
|
|
|
|
| |
| 6) | Fill solenoid valve | Jumper from “FILL” | Replace coil. Also check for frozen | |
|
| coil inoperative | terminal to “H” terminal | plunger. See valve instruction sheet. | |
|
|
| does not start fill. |
| |
|
|
|
|
| |
| 7) | Electrodes shorting to | Tank fills with electrode | Replace electrode assembly. If no | |
|
| ground. | wire disconnected from | remedy, check for improper wiring | |
|
|
| “HI” terminal. | (cut insulation) or electrode tips | |
|
|
|
| touching metal. | |
|
|
|
|
| |
| 8) | Dual Level Control | Tank does not fill | Replace Dual Level Control. | |
|
| faulty. | with electrode wire |
| |
|
|
| disconnected from “HI” |
| |
|
|
| terminal. |
| |
|
|
|
|
| |
D) Auto Refill is erratic. | 1) | Electrode shorting to | Tank fills with | Replace electrode assembly. | |
|
| ground completely or | electrode wire |
| |
|
| intermittently. | disconnected from “HI” |
| |
|
|
| terminal |
| |
|
|
|
|
| |
| 2) | Loose connection. | Visual. Check for “C” and | Push wire lead connector securely | |
|
|
| “HI” probe terminals as well | onto terminal(s). Replace connector | |
|
|
| as “FILL.” Also check | if wire is frayed or broken. | |
|
|
| neutral (white) wire at valve. |
| |
|
|
|
|
| |
| 3) | Dual Level Control | Tank does not fill with | Replace Dual Level Control. | |
|
| faulty. | electrode wires disconnected |
| |
|
|
| from “XL” and “H” terminals. |
| |
|
|
|
|
|