American Metal Ware Hot Water Boiler
IV) Trouble Shooting Auto Refill, Low Water Cutoff, and Dual Level Control System
PROBLEM | POSSIBLE CAUSE | SERVICE CHECK | REMEDY | |
|
|
|
|
|
A) Overfilling of water | 1) | Fill solenoid valve leaking | Visual. Water entering | Disassemble and clean out. May |
tank when power is |
| due to dirt or scale holding | tank continuously, and | require new plunger assembly. Caution |
off. |
| valve open, or worn | usually slowly. | is advised to avoid damage to valve. |
|
| plunger seat. |
| See valve instruction sheet. |
|
|
|
|
|
| 2) | Fill solenoid valve | Visual. | On valves without integral strainer: |
|
| installed backwards. |
| Install so that port marked “IN” is |
|
|
|
| connected to outside fresh water |
|
|
|
| supply. |
|
|
|
| On valves with integral strainer: |
|
|
|
| Install so that arrow points in |
|
|
|
| direction of tank, away from fresh |
|
|
|
| water supply. |
|
|
|
|
|
B) Overfilling of water | 1) | High electrode coated | Jumper from “HI” terminal | Remove electrode assembly. Clean both |
tank only when power |
| with scale, or faulty. | to metal enclosure stops | electrodes. If still no remedy and |
to unit is on. |
|
| fill. | connections are good, replace assembly. |
|
|
|
|
|
| 2) | Missing or faulty | Jumper “C” terminal | Make good secure connection. May |
|
| common connection for | (next to XL) to metal | require cleaning or replacement. |
|
| electrode circuit (“C” | enclosure stops fill. |
|
|
| terminal to metal |
|
|
|
| enclosure). |
|
|
|
|
|
|
|
| 3) | Fill valve connected to | Visual. | Connect “BLACK” wire lead to “FILL” |
|
| “HEAT” terminal. |
| terminal. |
|
|
|
|
|
| 4) | Dual Level printed | Jumper from “HI” to “C” | Replace Dual Level Control. |
|
| circuit board faulty. | does not stop fill. |
|
|
|
|
|
|
C) Auto refill fails to | 1) | No power at equipment. | Nothing operates on | Make sure main switch(es), fuse(s), |
fill water tank. |
|
| machine. | circuit breaker(s) provide power to |
|
|
|
| unit, that machine’s circuit |
|
|
|
| breaker is OK and power switch, if |
|
|
|
| provided, is on. |
|
|
|
|
|
| 2) | No water at equipment. | “Crack” fitting at | Make sure all water supply line |
|
|
| water inlet for pressure | valves are open. |
|
|
| check. |
|
|
|
|
|
|