Grindmaster RAPS200E, P200E Warning Electric Shock Hazard, Adjustments, Brew Volume Adjustment

Models: RAPS200E P200E

1 20
Download 20 pages 52.27 Kb
Page 5
Image 5
Adjustments

Adjustments

!WARNING: ELECTRIC SHOCK HAZARD

DANGEROUS ELECTRIC VOLTAGES ARE PRESENT NEAR ADJUSTABLE COMPONENTS. ALL ADJUSTMENTS SHOULD BE PERFORMED BY QUALIFIED SERVICE PERSONNEL ONLY.

All adjustable components are located under the top cover. To access these parts:

1)Unplug the brewer.

2)Remove the screw fastening the top cover. Remove the top cover.

Brew Volume Adjustment

The brew volume of the P200/RAPS200 brewer is controlled by its timer. The batch size is directly proportional to the timer setting. The timer adjustment is located under the top cover.

There will always be a small variation (+/- 5%) in level from batch to batch.

Before making the timer adjustment, do the following:

1)Brew a batch of water to determine where the level falls. Using a stop watch, determine the current brew time. Measure the volume of water.

2)To determine the desired time setting, use the following formula:

desired brew time

=

desired brew volume

_________________ X current brew time

 

 

current brew volume

Timer Adjustment

Two Batch Timer with Knob Adjustment, See Figure A:

1)This timer is adjustable from 15 seconds to 5 minutes. Locate the adjustment knobs under the top cover.

2)Set this timer by adjusting the knob. The batch selector switch picks the adjustment potentiometer which the timer will see.

A

P200/RAPS200 Brewers

Page 4

Page 5
Image 5
Grindmaster RAPS200E, P200E Warning Electric Shock Hazard, Adjustments, Brew Volume Adjustment, Timer Adjustment