Grindmaster P200E P200/RAPS200 Brewers, Heating Problems, Possible Cause, Service Check, Remedy

Models: RAPS200E P200E

1 20
Download 20 pages 52.27 Kb
Page 10
Image 10
Heating Problems

Troubleshooting: Filling, Heating, and Brewing (con’t.)

Heating Problems

The heating system consists of the following components:

Thermostat, located on the tank or on the front of top control panel under top cover.

Heating Element, located on top of tank under top cover.

Problem

Possible Cause

Service Check

Remedy

 

 

 

 

 

 

 

 

Tank does not

Thermostat faulty or

Make sure thermostat

Recalibrate thermostat. If no reme-

heat.

out of calibration.

is turned on.

dy or thermostat does not cycle,

 

 

 

replace thermostat.

 

 

 

 

 

Heater faulty.

Check resistance

If resistance is much different than 7

 

 

across elements with

to 10 ohms, replace heater.

 

 

wires disconnected.

 

 

 

 

 

Recovery time is very

Heater faulty.

See above.

See above.

long.

 

 

 

 

 

 

 

If you still need help, call our Service Department at (800) 568-5715, press 2 (Monday through Friday, 8 a.m. - 6 p.m. EST) or an authorized service center in your area. Please have the model and serial numbers ready so that accurate information can be given.

Prior authorization must be obtained from Grindmaster Technical Services Department for all warranty claims.

P200/RAPS200 Brewers

Page 9

Page 10