P200E Shuttle & RAPS200E Airpot/Shuttle Brewer Series
Operation and Instruction Manual
Table of Contents |
|
Installation and | |
Operation | 3 |
Adjustments | |
Cleaning | |
Service | 7 |
Troubleshooting |
|
Filling Problems | 8 |
Heating Problems | 9 |
Brewing Problems | 10 |
Exploded View for | 11 |
Exploded View for P200 (G version) | 12 |
Exploded View for | 13 |
Exploded View for RAPS200 (G version) | 14 |
15 | |
16 | |
Wiring Diagram for | 17 |
Prior authorization must be obtained from Grindmaster for all warranty claims.
Water
Installation
!WARNING: ELECTRIC SHOCK HAZARD!
INSTALLATION OF THIS APPLIANCE SHOULD BE PERFORMED BY QUALIFIED SERVICE PERSONNEL ONLY. IMPROPER INSTALLATION COULD RESULT IN ELECTROCUTION.
See
1)Remove the brewer from the packing material and attach its legs.
2)Position the brewer on a strong, stable table or counter. Check the level front to back and side to side. Adjust the legs to the correct level.
IMPORTANT:
THE PERSON INSTALLING THIS APPLIANCE IS RESPONSIBLE FOR ENSURING THAT ELECTRIC AND WATER CONNECTIONS MEET THE REQUIREMENTS OF THE NATIONAL ELECTRIC CODE, NATIONAL PLUMBING CODE, AND ANY LOCAL ORDINANCES.
1)Water inlet (supply) fitting is located at rear of unit.
2)Use 1/4" copper or flexible water line to prevent strain. Do not use low temperature plastic tubing. The connection is 1/4" flare.
3)Water line pressure must be from 30 to 70 psi.
4)Hot (up to 160F) or cold water may be used. Hot water offers faster recovery between brews, (Use cold water only if
5)Install a
6)Installing a filtering system can improve the taste of brewed coffee and extend the life of the brewer. If your water has high calcium (lime), chlorine, or iron content, this is especially important. The filter should be the lime inhibiting type if cold water is used. Contact our Customer Service Department to select the filter for your conditions.
Grindmaster Corporation™
4003 Collins Lane Louisville, KY 40245 USA
(502)
(800)
© Grindmaster Corporation, 1996 | 1004 FORM # |
Printed in the U.S.A. | Part # |