Cleaning the drain pump and non-return valve

Cleaning and care

Cleaning the drain pump and non-return valve

If water has not been pumped away at the end of a programme the drain pump or the non-return valve might be blocked. They are, however, easy to clean.

Take the filter combination out of the wash cabinet.

Release the locking clamp.

Lift up the non-return valve and rinse under running water.

The drain pump is situated under the non-return valve (see arrow).

Before replacing the non-return valve, check that the drain pump is free of extraneous objects.

Carefully replace the ron-return valve and secure with the locking clamp.