Electrical connection

Electrical connection

All electrical connection work must be carried out by a qualified electrician in compliance with local and national regulations.

For extra safety it is advisable to in- stall a residual current device (RCD) with a trip current of 30 mA.

Technical data is available on the data plate or in the enclosed wiring diagram.

The voltage, rated load and plug rating must correspond to that given on the data plate.

Conversion can only be undertaken in compliance with the conversion and wiring diagrams and only on machines without a steam condenser.

A conversion diagram is to be found at the back of the machine and on the back of the service panel.

The relevant wiring diagram is to be found on the left-hand side behind the plinth, attached to the base of the ma- chine.

The data plate with the relevant test cer- tification is on the rear of the machine and on the plinth (behind the service panel).

To remove the service panel and plinth:

Disconnect the machine from the mains.

Remove fixing screws “a”.

Take hold of both sides of the ser- vice panel and pull forward. Remove plinth fascia screws “b”. Disconnect earth lead if necessary. Remove plastic protective cap.

To reassemble:

Replace plastic protective cap, plinth fascia and service panel in reverse order.

Make sure the earth lead is recon- nected.

Also refer to the installation instructions enclosed.