Venting the dispensing system:

Programming special functions

4.Venting and setting the dosage on “DOS module G 60 or C 60” (special version)

Set the dosage selector on the DOS module to the “10” position (on DOS module C 60 only).

Turn the programme selector to the

f“STOP” position.

Switch off the machine.

Press 4 and 6 at the same time, hold them in and whilst doing so switch the machine on with the I-0button.

The current programme status “P...” appears in the display.

The p / 6 indicator light comes on.

Press 3 twice, “E02” (programming level 2) appears in the display.

Venting the dispensing system:

Turn the programme selector to the

pposition. “do1” appears in the dis- play.

Press 4 for 90 seconds.

The dispensing system is vented.

If only venting is required:

Switch the machine off with the I-0button.

Immediately after this: start the D (COLD) programme, so that after vent- ing any agents in the wash cabinet are diluted before being drained away.

Setting the dosage:

Set the amount to dispense according to the detergent manufacturer’s recom- mendations.

The machine needs 7 litres of water in the “Main wash” programme stage.

Example:

The detergent manufacturer recom- mends 4 ml cleaning agent per litre of water.

7 l x 4 ml/l = 28 ml.

2 ml . 1 sec. dispensing time; i.e. pro- gramming to 14 secs.

Turn the programme selector to the

qposition, the dispensing time in seconds appears in the display, e.g “10”.

Press 4 repeatedly or hold it in, until the number “14” appears in the display (dispensing time 14 seconds

. 28 ml - see example).

The dispensing time/amount is set.

Having changed a value or all values:

Press 6. “SP” appears in the display.

Press 6 again. The change has been recorded.

Value set:

If the dispensing system also needs to be vented:

Start the D (DRAIN) programme, so that after venting any agents in the wash cabinet are diluted before being drained away.