Miele G7859 manual “Final rinse” temperature holding time, Programming special functions

Models: G7859

1 56
Download 56 pages 59 Kb
Page 41
Image 41
“Final rinse” temperature holding time:

Programming special functions

Turn the programme selector back to the programme which needs to be changed. The actual value appears in the display after °C.

Press 4 or hold it in, until the re- quired value appears in the display.

“Final rinse” temperature holding time:

Turn the programme selector to the

f“STOP” position (the programm- ing level is only displayed in this switch position).

Press 3 again, “E06” (programm- ing level 6) appears in the display. Then:

Turn the programme selector back to the programme which needs to be changed. The actual value appears in the display after min.

Press 4 until the required value ap- pears in the display.

Having changed a value or all values:

Press 6. “SP” appears in the display.

Press 6 again. The change has been recorded.

6.Re-setting all changes back to the factory setting.

Turn the programme selector to the

f“STOP” position.

Switch off the machine.

Press 4 and 6 at the same time, hold them in and whilst doing so switch the machine on with the I-0button.

The current programme status “P...” appears in the display.

The p / 6 indicator light comes on.

Press 3 seven times, “E07” (pro- gramming level 7) appears in the dis- play.

Turn the programme selector to any setting (except “STOP”).

“00” or “PP” appears in the display. “00” = factory setting

(the electronic unit has not been re- programmed).

“PP” = the electronic unit has been reprogrammed.

If “PP” is displayed, press 4 to change from “PP” to “00”.

Press 6. “SP” appears in the display.

Press 6 again. Values which had been changed are now reset.

Important

If the hardness level setting in the water softener had been changed this will reset to the factory setting of 340 mg/l (19 °d). This will need to be reset to suit the hardness level in your area.