Please refer to the installation diagram supplied with the machine.

Furniture and fittings installed near the machine must be of a commercial standard able to withstand the effects of steam and condensed water.

The machine must be installed correctly and levelled.

Any uneveness in the floor level can be compensated for and the height of the machine raised or lowered by adjusting the four screw feet.

The machine can be installed in the following ways:

Freestanding:

Slot-in or at the end of a row:

The machine can be installed adjacent to other equipment or furniture or in a recess at least 60 cm wide and 60 cm deep.

Building under:

The machine should be positioned under a continuous worktop or sink drainer.

The niche must be at least 60 cm wide, 60 cm deep and 82 cm high.

If necessary the machine lid can be removed as follows:

Open the door.

Remove the fixing screws on the left and right hand sides using a cross slotted screwdriver.

Pull the machine lid approx. 5 mm forwards, lift upwards and remove.

Important for machines without a steam condenser:

The cabinet vent at the rear of the ma- chine must be connected to an on-site duct system.

Important for machines with a steam condenser:

To protect the underside of the worktop against water ingress, the protective foil (25 x 58 cm, self-adhesive) should be stuck under the worktop in the area of the steam condenser.