Programming special functions
In the event of a service call at a later date, any changes made to the fac- tory setting should be documented here.
Make a note of any changes made in
the “Value set: | ” box. | |
|
|
|
1.Setting the cold water inlet from: “Nominal water intake” to “Nominal water intake + 1 l”.
The amount of water taken into the ma- chine at each intake can be increased by 1 litre to a maximum of 9.5 litres.
Proceed as follows:
Turn the programme selector to the
f“STOP” position.
Switch off the machine.
Press 4 and 6 at the same time, hold them in and whilst doing so switch the machine on with the
The current programme status “P...” appears in the display.
The p / 6 indicator light comes on.
Press 3 once, “E01” (programming level 1) appears in the display.
Turn the programme selector to the
pposition,
“10” or “11” appears in the display. “10” = Nominal water intake
“11” = Nominal water intake + 1 l
Press 4 to change from “10” to “11” or vice versa.
Press 6. “SP” appears in the display.
Press 6 again. The change has been recorded.
Value set:
2. Selecting a second interim rinse
A second interim rinse can be pro- grammed in to improve interim rinsing in all programmes (except D COLD).
Turn the programme selector to the
f“STOP” position.
Switch off the machine.
Press 4 and 6 at the same time, hold them in and whilst doing so switch the machine on with the
The current programme status “P...” appears in the display.
The p / 6 indicator light comes on.
Press 3 once, “E01” (programming level 1) appears in the display.
Turn the programme selector to r , “30” or “31” appears in the display. “30” = One interim rinse.
“31” = Two interim rinses.
Press 4 to change from “30” to “31” or vice versa.
Press 6. “SP” appears in the display.
Press 6 again. The change has been recorded.
Value set:
33