AMERICAN METAL WARE® BREWERS
STANDARD FEATURES
Three options are available on this equipment; these options are available independently of each other. The features are described below:
Low Temp, No Brew: This option inhibits the initiation of a brew cycle in the event that water temperature in the tank is more than 5°F lower than the setpoint. In the event that the temperature is outside of the acceptable range, the WATER HOT light will be off. A brew cycle can only be initiated when the light is on if this option is employed; attempts to initiate a brew when the light is off will be ignored by the controller.
Automatic Bypass: This option allows the brewer to provide for bypassing of the grounds only for the large portion size by signaling a solenoid valve in the bypass circuit to open only when the large portion size is selected. The bypass amount is set by regulating the flow through the standard manual bypass valve provided on all units (see Bypass Adjustment).
These features can be removed at no charge by ordering the following options: |
|
| |
Option 250 eliminates | leaves auto bypass only |
Option 251 eliminates | leaves |
Option 252 eliminates | leaves |
P430/330 |
|
Opt 253 eliminates low temp/no brew | leaves |
Opt 258 eliminates low temp/no brew and auto bypass | leaves |
Opt 259 eliminates low temp/no brew and | leaves auto bypass only |
ADJUSTMENTS
WARNING: ELECTRICAL SHOCK HAZARD! DANGEROUS ELECTRIC VOLTAGES ARE PRESENT NEAR ADJUSTABLE COMPONENTS. ONLY QUALIFIED SERVICE PERSONNEL SHOULD MAKE ADJUSTMENTS.
Components for adjustment of brew volume/brew timing and of temperature are located behind the small access panel located in the
•Turn off electric power to unit at the main breaker assigned to the unit (or disconnect the cord where applicable) when removing the top panel.
•Remove the screws fastening the appropriate panel to the body.
•Remove the panel.
TEMPERATURE ADJUSTMENT
Brew water temperature can be adjusted by turning the knob on the main controller located behind the controller access panel. Temperature adjustment range is from 175°F to 202°F. Adjustment for temperature should be made after measuring the temperature of the water dispensed from the brew head by the following procedure.
1)Remove sprayhead from brewer and set aside.
2)Place a container under the outlet.
3)Press START and, using a thermometer, measure the temperature of the water being dispensed.
4)If a higher temperature is desired, rotate the TEMPERATURE ADJUSTMENT knob clockwise. If a lower temperature is desired, rotate the temperature adjustment knob counterclockwise.
5)If water temperature setting has been increased, wait until heater has cycled and then follow steps 3 and 4 again. If water temperature setting has been decreased, brew a large portion of water and repeat steps 3 and 4.
6)Continue this procedure until desired brew temperature is achieved.
7)Replace sprayhead.
BREW TIMING/BREW VOLUME ADJUSTMENT
Brew volume is adjusted by adjusting the timer values of the controller (refer to Temperature and Brew Timing Controls). The brewer timers settings are preset at the factory to the following values:
Small brew | (0.75 gal.) | 120 sec. |
Medium brew | (1.25 gal.) | 165 sec. |
Large brew | (1.75 gal.) | 230 sec. |
Before adjusting brew timing, brew a batch of water and measure the brew volume. Record this value.
To adjust brew timing:
•Remove controller access panel.
•If making timer adjustments on a twin brewer, slide the brewer selector switch to the appropriate position. On single brewers, the switch should always be in the left position.
•Press the SELECT button momentarily; a LED will light up to indicate which timing selection is being displayed on the alphanumeric display. The top LED corresponds to the small portion size, the middle LED corresponds to the medium size, and the lower LED corresponds to the large setting. Note the timer value displayed. The new timing should be calculated by the following:
Desired Brew Time = Desired Brew Volume
Current Brew Volume
•After selecting the appropriate side and portion timer, adjust the timer value to the desired value by pressing the UP or DOWN buttons on the controller. Hold the button down until the desired value is displayed; then press the SELECT button on the controller.
•Brew a batch of water and measure volume dispensed. Repeat procedure as necessary until desired volume is dispensed.
•Replace access panel.
Page 4