![Brew cycle will not start (cont’d)](/images/new-backgrounds/64757/6475717x1.webp)
AMERICAN METAL WARE® BREWERS
TROUBLESHOOTING GUIDE (cont’d)
Problem | Possible Cause | Solution |
Brew cycle will not start (cont’d) | • Brew valve faulty. |
| |
| • Touchpad faulty. |
| |
| • Controller faulty. |
•Check to see if there is 120Vac across brew valve terminal. If there is 120Vac across terminals and brew valve is not open,replace valve.
•Check to see that touchpad connections to control board are secure. If connections are secure, other functions appear normal and touchpad will not initiate a brew cycle, replace touchpad.
•Check to see that the power is supplied to the controller by following the Troubleshooting section on Filling Problems. Once touchpad and momentary switch integrity is assured (see above), initiate a brew cycle and check 120Vac across brew valve. If there is not 120Vac across brew valve, replace control board.
Sprayhead will not stop dripping water
•Brew valve not closing completely.
•Water in tank boiling.
•Visually inspect brew valve at hose connections. Clean lime from valve. Seat, cup or entire valve may need replacement.
•Remove sprayhead and determine if drip is coming from overflow. Reduce tank temperature.
If you still need help, call our service department at (800)
Prior authorization must be obtained from Grindmaster Corporation’s Technical Services Department for all warranty claims.
Page 9