Brew cycle will not start (cont’d)

AMERICAN METAL WARE® BREWERS

TROUBLESHOOTING GUIDE (cont’d)

Problem

Possible Cause

Solution

Brew cycle will not start (cont’d)

• Brew valve faulty.

 

 

• Touchpad faulty.

 

 

• Controller faulty.

Check to see if there is 120Vac across brew valve terminal. If there is 120Vac across terminals and brew valve is not open,replace valve.

Check to see that touchpad connections to control board are secure. If connections are secure, other functions appear normal and touchpad will not initiate a brew cycle, replace touchpad.

Check to see that the power is supplied to the controller by following the Troubleshooting section on Filling Problems. Once touchpad and momentary switch integrity is assured (see above), initiate a brew cycle and check 120Vac across brew valve. If there is not 120Vac across brew valve, replace control board.

Sprayhead will not stop dripping water

Brew valve not closing completely.

Water in tank boiling.

Visually inspect brew valve at hose connections. Clean lime from valve. Seat, cup or entire valve may need replacement.

Remove sprayhead and determine if drip is coming from overflow. Reduce tank temperature.

If you still need help, call our service department at (800) 568-5715 (Monday through Friday, 8 am - 6 pm EST) or an authorized service center in your area. Please have the model and serial numbers ready so that accurate information may be given.