Replaces Page 13

440V Connection

(G0446/G0539)

To connect this machine to 440V three-phase, you must purchase one LR3D076 overload relay and one LR3D325 overload relay.

If you do not have three-phase power available to the G0446/G0539 sander, you will have to install a phase converter such as the Grizzly H3741 Phase Converter.

When using a phase converter, the power from the manufactured power leg (sometimes called the wild wire) can fluctuate. Connect the manu- factured power leg to the S terminal to prevent damage to the transformer. The wire from the S terminal can handle some fluctuation because it goes directly to the motor. The power going to the R and T terminals goes to the transformer and must be consistent to prevent damage.

To wire the Model G0446/G0539 to 440V:

1.Disconnect the sander from the power source!

2.Open the electrical box located on the back of the machine.

3.Remove the wire labeled “1” at the 220V terminal of the control power transformer (Figure 7) and connect it to the 440V termi- nal.

 

TRANSFORMER

0

440V

0

200V

220V

0

2

3

1

4.Remove the LR3D340 overload relay (Figure 8), and replace it with an LR3D325 (17-25A) type, with the dial set to 18A.

Transformer

LR3D325

 

LR3D076

 

 

 

Figure 8. Overload relay.

5.Remove the LR3D086 overload relay (Figure 8), and replace it with an LR3D076 (1.6-2.5A) type, with the dial set to 1.7A.

6.Wire the sanding belt, conveyor belt, and table elevation motors as shown on the diagrams on the inside of each motor wire cover.

Note: The circled references on the diagrams represent labels on the wires. Also, Figure 9 below has been provided for your reference and is current at the time of writing. However, always use the diagram on the wire cover that comes with your motor!

SANDING MOTOR

 

 

 

CONVEYOR MOTOR

W5

U5

V5

TABLE UP/DOWN MOTOR

U2

V2

W2

 

 

 

 

 

 

W2

U2

V2

U2

V2

W2

U5

V5

W5

W6

U6

V6

U5

V5

W5

U1

V1

W1

U1

V1

W1

U1

V1

W1

 

 

 

 

 

 

 

 

 

 

440V

 

 

440V

 

 

440V

 

 

 

 

Figure 9. 440V motor wiring connection.

Figure 7. The “1” wire should be connected to

the 440V terminal.

G0446, G0539, G0571 (Mfg. Since 9/10)

-3-

Page 4
Image 4
Grizzly manual 440V Connection G0446/G0539, Motor wiring connection