SECTION 2: CIRCUIT REQUIREMENTS

110/220V Operation

The Model G0583 features a single phase 110V/220V 1 HP motor, which is prewired to 110V.

Amperage Draw

 

 

110V

9

Amps

220V

4.5

Amps

Circuit Breaker Requirements

Use the following guidelines when choosing a circuit breaker (circuit breakers rated any higher are not adequate to protect the circuit):

Circuit Breaker

 

110V

15 Amp

220V

10 Amp

Always check to see if the wires in your circuit are capable of handling the amperage draw from your machine, as well as any other machines that could be operating on the same circuit. If you are unsure, consult a qualified electrician.

A fire may occur if your particular electrical configuration does not comply with local and state codes. The best way to ensure compli- ance is to check with your local municipality or a qualified electrician.

Plug and Recepticle Requirements

The motor is prewired to 110V and no plug replacement is required. For 220V connection, rewire the motor as in Figure 2, and install a NEMA 6-15 plug (Figure 1). You may also “hard- wire” the dust collector directly to your panel, pro- vided you place a disconnect near the machine. Check the electrical codes in your area for specif- ics on wiring requirements.

Figure 1. NEMA 6-15 plug and receptacle.

������

����������

������ �������

�����������������

������

 

 

��������

 

�����������

 

������������

������

 

����������

 

������ ���������

 

���������������

������

 

 

��������

�����������

������������

Figure 2. 110V/220V motor wiring diagram.