G9742 Wiring Diagram

Disconnect power from machine before performing any electrical service. Failure to do this will result in a shock hazard leading to injury or death.

110V

Power Supply

LadHot

Neutral

Ground

 

 

 

Green

White

Black

Pushbutton

Magnetic

Switch

110V

 

Connection

Capacitor

Motor

Bandsaw Motor

Green

Capacitor Cover

 

 

 

Red

 

 

 

Neutral

Black

Wire number

 

 

Wire Color

White

 

 

 

 

1

= Black

Black

Hot

Gray

 

 

2

= Yellow

 

 

Yellow

 

 

3

= Red

 

 

 

4

= Gray

Bandsaw Motor

Electrical Box

220V

Power Supply

LadHot

NeutralHot

Ground

 

 

 

Green

White

Black

Pushbutton

Magnetic

Switch

220V

 

Connection

Capacitor

Motor

Bandsaw Motor

Green

Capacitor Cover

 

 

 

Red

Red

 

 

 

Hot

Black

Wire number

 

 

 

 

 

Wire Color

White

 

 

Gray

 

 

1

= Black

Black

Hot

Gray

 

 

 

2

= Yellow

 

 

 

 

 

Yellow

 

 

 

 

3

= Red

 

 

 

 

4

= Gray

Bandsaw Motor

Electrical Box

-32-

G9742 5" x 6" Metal Cutting Bandsaw

Page 34
Image 34
Grizzly owner manual G9742 Wiring Diagram, 110V Connection, 220V Connection