Filter Capacity
The G9956
To calculate the recirculating rate for a given volume:
Step 1. Calculate, how long it takes to circulate all the volume of air in a room with the double air fil- ter; where W = Width, L = Length and H = Height of your room, in feet. The rate of air movement for the air filter is 1400 cubic feet per minute.
W' x L' x H' = Minutes for circulating 1 time 1400
Step 2. Calculate how many times per hour the volume is recirculated through the double air filter by dividing 60 minutes by the amount of time it takes to circulate the volume once. The result is listed as times per hour.
Step 1: 20' x 20' x 8' = 5000 | = 2.28 Minutes | ||||
| 1400 | 1400 |
| ||
Step 2: | 60 | = 26.3 Times per Hour | |||
| 2.28 | ||||
|
|
|
|
|
|
|
|
|
|
|
|
Mounting
Preparation
It is very important that the double air filter is supported properly. Please use these guidelines when preparing to mount the unit.
•For the sake of clarity, the surface where the eyebolts attach will be called the top through- out the manual.
•Make sure that an electrical outlet with a properly grounded receptacle is available at your location of choice.
•The double air filter must be supported by joists when hanging. These joists should be capable of supporting at least 150 lbs. DO NOT attach the double air filter to sheet rock, press board or paneling. These cannot sup- port the filter and it may fall.
•To avoid hitting your head on the double air filter, make sure there is enough clearance between the unit and the ground (at least seven feet). This is especially important in a basement. If possible, position the air filter in an area that has little or no foot traffic but still offers easy access to the switch and filters.
Eye Bolts |
|
Components and Hardware Needed | Qty |
Eye bolts | 4 |
Hex Nuts | 4 |
Tools Needed |
|
Wrench 12mm | 1 |
To attach the eye bolts: |
|
1.If the nuts are not already on the eye bolts, thread one onto each eye.
2.Thread one eye bolt into each hole on the top of the double air filter. Use as much of the available thread as possible.
3.Tighten the nuts on each eye bolt until the eyes will not move by hand. DO NOT over tighten.
G9956