Model H3253, H3254, H3255 Spray Gun -11-
The atomizing cap needs to be adjusted
for horizontal or vertical spraying patterns.
Spraying in the wrong direction may lead
to material build up on the atomizing c ap
horn. Many performance problems are
caused by clogged atomizin g holes on the
atomizing cap horns (see Cleaning on
Page 13).
Figure 9. Set up for horizontal stroke
direction with vertical fan pattern.
Figure 10. Set up for vertical spray stroke
with horizontal fan pattern.
Stroke
Holes
Figure 11. Fan adjustment.
Rotating the pat tern adjustment control in
Figure 10 will give you a range between
the two patterns in Figu re 11.
Stroke
Pattern Control
Atomizing Cap and Fan Adjustments
Model H3254 fan is controlled by the
nozzle used. Three nozzles are included—
round, fan, and angled. Select the shape
that best suits your appli cation.