PROBLEM

 

 

CAUSE

 

 

 

 

 

ACTION

 

Motor runs hot

 

 

3.

Compressor

is

 

 

3.

Do not allow the compressor to run over

 

 

 

 

 

 

 

exceeding

its duty-

 

 

 

its recommended duty cycle.

 

 

 

 

 

 

 

cycle.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pressure relief

 

 

1.

Faulty

pressure

 

 

 

1.

Turn compressor off, unplug from power

 

 

valve

stays

 

 

 

switch, unit is trying

 

 

 

supply, drain tank. DO NOT USE until

 

 

open

and

 

 

 

to overpressure

the

 

 

 

switch is repaired or replaced.

 

 

motor

won’t

 

 

 

tank.

 

 

 

 

 

2.

Relief valve is relieving pressure too

 

 

stop running.

 

 

2.

Faulty

pressure

 

 

 

early, test pressure relief and repair or

 

 

 

 

 

 

 

relief valve.

 

 

 

 

 

 

replace.

 

 

 

 

 

 

 

 

 

 

 

 

 

Air leaks from

 

 

1.

Faulty check valves.

 

 

 

1.

Clean dirt or debris from rubber mem-

 

 

p r e s s u r e

 

 

 

 

 

 

 

 

 

 

brane of check valve after removing top

 

 

switch

 

 

 

 

 

 

 

 

 

 

 

nut.

 

 

 

 

 

 

2. faulty

pressure

 

 

2.

Repair or replace pressure switch.

 

 

 

 

 

 

 

switch.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Air is

dirty or

 

 

1. Tank is not drained.

 

 

 

1. Open drain cocks on both tanks and make

 

 

has excessive

 

 

 

 

 

 

 

 

 

 

certain all condensation water is drained

 

 

moisture.

 

 

2.

Delivery pipes

are

 

 

 

 

out.

 

 

 

 

 

 

 

 

2.

Remove delivery pipes, clean out and

 

 

 

 

 

 

 

dirty.

 

 

 

 

 

 

replace.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

-16-

Model H4517/H4518Air Compressors

Page 18
Image 18
Grizzly H4517/H4518 instruction manual Early, test pressure relief and repair or