| PROBLEM |
|
| CAUSE |
|
|
|
|
| ACTION | ||||
| Motor runs hot |
|
| 3. | Compressor | is |
|
| 3. | Do not allow the compressor to run over |
| |||
|
|
|
|
|
| exceeding | its duty- |
|
|
| its recommended duty cycle. |
| ||
|
|
|
|
|
| cycle. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
| Pressure relief |
|
| 1. | Faulty | pressure |
|
|
| 1. | Turn compressor off, unplug from power |
| ||
| valve | stays |
|
|
| switch, unit is trying |
|
|
| supply, drain tank. DO NOT USE until |
| |||
| open | and |
|
|
| to overpressure | the |
|
|
| switch is repaired or replaced. |
| ||
| motor | won’t |
|
|
| tank. |
|
|
|
|
| 2. | Relief valve is relieving pressure too |
|
| stop running. |
|
| 2. | Faulty | pressure |
|
|
| early, test pressure relief and repair or |
| |||
|
|
|
|
|
| relief valve. |
|
|
|
|
|
| replace. |
|
|
|
|
|
|
|
|
|
|
|
| ||||
| Air leaks from |
|
| 1. | Faulty check valves. |
|
|
| 1. | Clean dirt or debris from rubber mem- |
| |||
| p r e s s u r e |
|
|
|
|
|
|
|
|
|
| brane of check valve after removing top |
| |
| switch |
|
|
|
|
|
|
|
|
|
|
| nut. |
|
|
|
|
|
| 2. faulty | pressure |
|
| 2. | Repair or replace pressure switch. |
| |||
|
|
|
|
|
| switch. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
| Air is | dirty or |
|
| 1. Tank is not drained. |
|
|
| 1. Open drain cocks on both tanks and make |
| ||||
| has excessive |
|
|
|
|
|
|
|
|
|
| certain all condensation water is drained |
| |
| moisture. |
|
| 2. | Delivery pipes | are |
|
|
|
| out. |
| ||
|
|
|
|
|
|
| 2. | Remove delivery pipes, clean out and |
| |||||
|
|
|
|
|
| dirty. |
|
|
|
|
|
| replace. |
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Model H4517/H4518Air Compressors |