Grizzly H7507 owner manual Dust Collection, Recommended CFM at Dust Port 225 CFM

Models: H7507

1 32
Download 32 pages 27.61 Kb
Page 20
Image 20

19.Center the guard over the table opening and attach the guard assembly to the top of the fence boards with the two provided wood screws, as shown in Figure 29.

Figure 29. Attaching router guard.

20.Adjust the guard horizontally (if necessary) by using the horizontal bracket slots and wood screws.

21.Adjust the height of the guard 18" higher than the workpiece height by using the vertical bracket slots and carriage bolt/wing nuts.

22.Connect the top of the guard to your dust col- lection system with a 3" adapter.

If you change router bits, the fence pieces must be adjusted in/out so there is not more than 18" clearance between the router bit and the fences.

-18-

Dust Collection

DO NOT use the Model H7507 without an ade- quate dust collection system. An attached router will create substantial amounts of wood dust while operating. Failure to use a dust collection system can result in short and long-term respiratory illness.

Recommended CFM at Dust Port: 225 CFM

Do not confuse this CFM recommendation with the rating of the dust collector. To determine the CFM at the dust port, you must consider these variables: (1) CFM rating of the dust collector,

(2)hose type and length between the dust col- lector and the machine, (3) number of branches or wyes, and (4) amount of other open lines throughout the system. Explaining how to cal- culate these variables is beyond the scope of this manual. Consult an expert or purchase a good dust collection "how-to" book.

The Model H7507 features a clear 3" plastic guard that can be connected to a dust collector or a dust collection system.

Model H7507 (Mfg. since 3/05)

Page 20
Image 20
Grizzly H7507 owner manual Dust Collection, Recommended CFM at Dust Port 225 CFM