Grizzly H7668 instruction manual Atomizing Cap and Fan Adjustments

Models: H7668

1 24
Download 24 pages 52.39 Kb
Page 13
Image 13
Atomizing Cap and

Atomizing Cap and

Fan Adjustments

The atomizing cap needs to be adjusted for horizontal or vertical spraying patterns. Spraying in the wrong direction may lead to material build up on the atomizing cap horn. Many performance problems are caused by clogged atomizing holes on the atomizing cap horns (see Cleaning on Page 15).

Holes Manual background

Stroke

Figure 12. Set up for horizontal stroke

direction with vertical fan pattern.

Stroke

Figure 13. Set up for vertical spray stroke

with horizontal fan pattern.

Rotating the pattern adjustment knob in Figure 14 will give you a range between the two patterns in Figure 15.

Pattern Adjustment Knob

Figure 14. Pattern adjustment knob.

Figure 15. Fan patterns.

Model H7668 Spray Gun w/Pressure Cup

-13-

Page 13
Image 13
Grizzly H7668 instruction manual Atomizing Cap and Fan Adjustments