H7945/H7946/H7995 26° Angle Nailer -13-
CLEANING & LUBRICATING Cleaning
Use an automotive grade solvent such as
Sprayway C-60® (G25 44 in the Grizzly
catalog) to clean the nose assembly of the
nailer. Always be sure that the nailer is dry
before using it again.
Do not allow dus t, chips, or sand into the
air connectors or into the bo dy of the nail-
er; this may result in leaks and da mage to
the nailer and the air co uplings.
Lubricating
Special pneumatic tool oil has been
included with you r new Grizzly nailer to
help maintain its useful life. Place two to
six drops of oil in the nailer air inlet (as
shown in Figure 10) every 2 hour s of
continuous use.
Wipe of f any excess oil near the nailer
exhaust to avoid dust build-up. When
the oil t hat was included wit h your nailer
has been completely used, replace with
Grizzly Model G2820 Pneumat ic Tool Oil.
An efficient alternative to oiling your tool
by hand is to install a lubri cator in your air
compressor line. If your air compressor
line already has a lubricator, th en regular
lubrication of your nailer will not be neces-
sary. Just make sure there is always oil in
the lubricator.
Figure 10. Lubricating the nailer at the
air inlet.
Never use gasoline to clean this tool.
Use extreme caution when using any
solvent cleaner. Always clean the tool
in a well-ventilated area and never if
sparks or open flames are present.
Remember that electrical machinery
can produce sparks during normal
operation. Ignoring this warning can
cause serious personal injury or even
death!