2.Screw the cup onto the top of the body.

3.Install the barbed hose fitting into the base of the gun handle and tighten in place with the lock nut.

4.Secure the air hose to the barbed fit- ting with a hose clamp, or use a 14" NPT quick connect fitting (not includ- ed).

Note: A 14" NPT quick connect set-up will make operation and maintenance tasks easier.

5.Attach the spray gun to an air supply regulated between 45 and 60 PSI.

Note: For the best results, use a hose dedicated for spray use only. Do not use a hose that has been used with an in-line oiler or other possible con- taminant.

If you need additional help with this assem- bly, call our Technical Support at: (570) 546-9663.

Controls

Atomizing Cap

Cup

 

 

Pattern Control

Trigger

Fluid Control

 

Air Flow Control

 

Figure 4. H8115 Controls.

Atomizing Cap

Cup

 

Fluid Control

Trigger

Pattern Control

Air Flow Control

 

Figure 5. H8117 Controls.

1.Fluid Control: Controls the volume of material that travels through the fluid tip.

2.Pattern Control: Adjusts the spray pattern from a round pattern to a wide fan.

3.Air Flow Control: Controls the fluid pressure inside the spray gun.

4.Atomizing Cap: Controls the spray pattern from vertical to horizontal.

5.Trigger: Two stage trigger. Stage one only releases compressed air for blowing off the work piece. Stage two sprays material.

6.Cup: Holds material; includes a vent- ed cap.

-10-

Model H8115/H8117 Spray Gun

Page 10
Image 10
Grizzly H8115 owner manual Controls