EYE INJURY |
HAZARD! |
Wear protective |
equipment when |
using this tool. |
Operation |
1.Connect the tool to compressed air regulated at 90 PSI.
2.Hold the sander firmly and press the throttle lever (Figure 3) to turn it ON.
Throttle Lever |
Regulator |
Knob |
Figure 3. Sander controls.
3.Turn the regulator knob (Figure 3) to adjust the speed of the sanding disc.
4.Remove pressure on the throttle lever to stop the sander.
5.When the sandpaper loses its effective- ness, remove sandpaper from the pad and install a new disc.
6.To avoid accidental starting, discon- nect the sander from the air supply when it is not in use or when perform- ing maintenance.
Model H8215 6" Dual Action Air Sander
LUNG/EAR
INJURY HAZARD! Wear protective equipment when using this tool.
ACCIDENTAL
START HAZARD! Disconnect before service or tool changes.
AIR PRESSURE
HAZARD!
Never exceed 120
PSI.
Daily Maintenance
The dual action sander MUST have
Run the sander for a few minutes to eject excess oil, then wipe the tool down with a rag and begin sanding. Oil the tool after use or storage.
These procedures should be done after each use:
•Wipe the housing and tool bits with a dry cloth, or blow off the dust and debris with compressed air.
•Check for damage to tooling, hoses, housing or other accessories.