Model T10006 50 Kg Digital Crane Scale-8-
Scale Battery
The scale will automati cally display the
current scale batter y voltage when you
turn the scale ON and OFF. To check the
voltage during use, press the MR button
on the remot e control and the screen will
display SHIFT. Press the F1 button and the
screen will display U X.XX. To return to the
main display, press MR again.
When the battery voltag e is lower than
U 5.80, the screen will fl ash to alert you.
The scale will continue to display for
approximately one minute longer u ntil -Lb-
is displayed on the screen, and then turn
OFF automatically. T he scale wi ll need to
be charged before furthe r use.
To recharge the batter y:
1. Turn the scale OFF.
2. Connect the supplied adapter into the
socket located in the back of the scale,
then into a grounded 110V outlet. The
light turns orange while charging and
turns red when charging is complete.
Note: The battery should re-charge for
at least 8 hours.
Hold Function
When the load has been added to the
scale, wait until the STB light goes off sig -
nifying that the load is stable (Figure 4). If
you would like the weight value to rem ain
on the screen, press the HOLD button on
the remote con trol. To clear the screen,
press the HOLD button ag ain.
Current Zero Value:
The current zero value is the tare weight
that was selected. To view the cur rent
zero scale value, press the MR but ton and
the screen will display SHIFT. Press t he
butto n on the remote co ntrol to
display the current zero valu e.
Advance Tare Weight
To input a known tare weight before weigh-
ing an item, press MR and the screen
will display SHIFT. Press TARE, and the
screen will display 000.00. To input the
desired weight, scroll to the righ t by press-
ing the ri ght arrow (TARE) on t he remote
control until you come to the numbe r that
you would like to change. To increase
the number from zero, press the left but-
ton (
) on t he remote control. To
decrease the number, press CLEAR on
the remote contro l. When you are satis-
fied with the current numbe r, pr ess the
M+ to move to the left. To submit the tare
amount, press MR a nd the TARE light w ill
come on the scale, automatically deduct-
ing the imputed tare weight. T he tare
weight will stay the s ame until the sc ale is
turned OFF.
Clear Function
To cle ar, press the CLE AR button and
the screen will flash CLr. If you wo uld
like to approve the clear command, press
MR an d the screen will display 888.8 8,
confirming th e deletio n. If you would like
to cancel the clear command , press the
CLEAR button ag ain. The sc reen will di s-
play noCLr canceling the deletion.
Search Overload Times
To review how many instances the sc ale
has been overloaded, press the MR button
and the screen w ill display SHIFT. Pre ss
the CLEAR butt on and the screen will
display OL=XX, showing how m any times
the scale has exceeded its ma ximum
capacity.
Display Function
To change the brightness of the disp lay,
press F1. Display brightness ranges from 1
(minimum light) to 5 (maximum lig ht). The
default display setting i s 2.