Hafler GX2300CE, GX2600CE manual Design Features, off before, operating this, switch

Models: GX2600CE GX2300 GX2600 GX2300CE

1 44
Download 44 pages 5.49 Kb
Page 13
Image 13
Design Features

Design Features

70V

 

 

 

100v 4

 

 

 

 

8

2

 

CH A

 

Load

 

 

Power

2300

 

 

 

 

70V

 

 

 

100v 4

 

 

 

 

8

2

 

CH B

 

1

9

2

3

 

 

 

 

 

12

 

 

 

 

 

 

 

-18

-15

-12

 

 

 

-21

 

-9

 

 

 

-24

 

-6

 

 

 

-27

 

-3

 

Channel A

 

-32

 

 

 

 

-38

 

 

 

 

 

OFF

0dB

signal

protect

Stereo Mono

 

 

 

70V

 

 

 

 

 

 

 

 

 

 

100V

 

 

 

 

 

-18

-15

-12

clip

thermal

-21

 

-9

 

 

 

-24

 

-6

 

 

 

-27

 

-3

 

Channel b

 

-32

 

 

 

 

-38

 

 

 

 

 

OFF

0dB

4

7

8

 

 

HP

 

180˚

Delay

 

 

Crossover LP

 

 

 

 

must

 

 

 

Full

 

 

 

CD EQ +0

2

6

Phase choose

300W

 

 

 

one

 

2– 8

 

 

 

 

 

0”-

only

 

 

 

 

+10 dB

 

 

6”-

Audio GND

 

 

Freq

500Hz –

 

12”-

 

 

 

18”-

Chassis Float

 

 

 

800Hz –

 

24”-

 

 

+

CH A

 

 

 

 

30”-

 

BIAMP STEREO

 

 

ON

 

IN

 

 

 

 

 

HP

 

180˚

 

 

 

 

Crossover LP

 

 

+

+

 

 

Full

 

Phase

 

 

CD EQ +0 2

6

 

Delay

 

 

+10 dB

 

 

0”-

 

 

 

Freq

 

 

 

6”-

must

 

 

 

500Hz –

 

12”-

choose

 

 

 

 

 

 

18”-

one

 

 

 

800Hz –

 

24”-

 

 

 

 

 

 

30”-

only

600W

 

 

 

 

 

 

 

300W

CH B

 

 

 

 

ON

4– 16

2– 8

IN

(Mono)

 

 

 

Mono,70V,100V

 

 

 

 

 

 

 

 

Class 2 wiring

 

For 70V, 100V, or Mono

Use CH B input

Load across RED terminals

Set load switches to one half load impedance

Attention: Utiliser un fusible de rechange de même type.

CAUTION: For continued protection from risk of fire, replace only with same type and rating of fuse.

 

A Division of

 

Rockford Corp.

®

Tempe, AZ 85281

GX 2 3 0 0 Made in the U.S.A.

300 W Stereo, 2– 8

600W Mono, 70V,100V

250W

250V T7A 115V~

50-60Hz

 

5

15

6

 

10

 

 

11

13

14

16

1. Recessed Front Panel - Prevents switches and controls from acci-

10. Output Binding Posts - Connects the speaker array to the ampli-

dentally being adjusted or broken.

 

 

 

 

fier. These jacks allow bare wire, spade lugs or dual banana

2. Power Switch - Turns the amplifier ON and OFF

 

 

plugs to be connected to the amplifier.

 

 

 

 

 

 

3. Power LEDs - Verifies that the amplifier channel is ON

 

11. Internal Fans - internal fans keep the amplifier circuitry cool.

 

Allow a minimum of 3" clearance on the front and back of the

4. Status LEDs - Displays the status of the amplifier. The LEDs are as

amplifier vents for adequate ventilation.

 

follows: SIGNAL indicates if signal is present; CLIP illuminates if

 

12. Chassis/Float ground switch - Isolates Audio GND and helps

the amplifier is being overdriven; PROTECT illuminates if the

eliminate noise in the signal chain. With the switch in “Chassis”

amplifier is experiencing a “short” in the speaker array; THER-

position, the Audio GND is connected to chassis ground. In the

MAL illuminates if the amplifier has shut down due an overheat-

“Float” position, the Audio GND is isolated (floating) from the

ing condition.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

chassis.The chassis is permanently connected to earth (safety)

5. Female XLR & 1/4" TRS Input Jacks - Feeds input signal to the

ground.

 

 

amplifier using industry standard male XLR or 1/4" TRS

 

 

 

 

 

(tip/ring/sleeve) plugs.

 

 

 

 

 

13. Mains Power Fuse - Protects the “mains” electrical circuit in

6. Crossover/Delay/Phase/CD EQ - Each channel is

 

 

case abnormal current draw from the amplifier is experienced.

configurable for typical 2-way speaker systems.

 

 

14. Mains Power Connector - Connects AC Voltage to the amplifi-

7. Stereo/Mono Switch - This dual purpose switch is used to select

er. The power connector is safety approved IEC type 320. The

the operating mode of the amplifier. In Stereo mode the amplifi-

earth (safety) ground pin of the power connector is permanent-

er can be configured for standard 2-channel stereo operation. In

ly connected to the chassis. This

connection

is capable of

Mono mode the amplifier can be configured for Standard Bridge

shunting in excess of 30A of fault current.

 

mono, 70V mono or 100V mono operation. Turn amplifier off

 

 

 

 

before operating this switch.

 

 

 

 

 

15. Stereo/Biamp Switch - This dual purpose switch selects either

8. Level Controls - Adjusts the gain of the amplifier.

 

 

standard 2-channel stereo mode or 1-channel in, 2 channels

 

 

out Biamp mode. Turn amplifier

off before

operating this

9. Load Switch - Selects the speaker impedance or transformer voltage

switch.

 

 

that will be connected the output binding posts. In Standard Mode

 

 

 

 

 

the

amplifier

can

drive

2,

4

or

8

16. Removable Rear Panel - 8 screws can be removed to service

speaker loads. In Constant Voltage Mode the amplifier can drive an

fans and internal components without unracking the amplifier.

array of speakers using 70V or 100V transformers.

 

 

 

 

 