Hafler GX2300CE, GX2600CE manual BRIDGE MONO MODE GX2300/GX2600, 70V MONO MODE GX2300/GX2600

Models: GX2600CE GX2300 GX2600 GX2300CE

1 44
Download 44 pages 5.49 Kb
Page 22
Image 22
BRIDGE MONO MODE (GX2300/GX2600)

BRIDGE MONO MODE (GX2300/GX2600)

 

70V

 

 

100v

4

 

 

8

2

CH A

 

Load

Power

2300

 

 

 

 

70V

 

 

100v

4

 

 

8

2

CH B

 

 

 

HP

 

180˚

Delay

 

Crossover LP

 

 

 

Full

 

must

 

 

CD EQ +0

2

6

Phase choose

300W

 

 

 

one

 

2– 8

 

 

 

 

 

0”-

only

 

 

 

 

+10 dB

 

 

6”-

Audio GND

 

 

Freq

500Hz –

 

12”-

 

 

 

18”-

Chassis

Float

 

 

 

800Hz –

 

24”-

 

 

+

CH A

 

 

30”-

 

IN

BIAMP STEREO

 

 

ON

 

 

 

HP

 

180˚

 

 

 

 

Crossover LP

 

 

+

+

 

 

Full

 

Phase

 

CD EQ +0 2

6

 

Delay

 

 

+10 dB

 

 

0”-

 

 

 

 

 

 

 

6”-

must

 

 

 

Freq

500Hz –

 

12”-

choose

 

300W

 

 

18”-

 

 

 

800Hz –

 

24”-

one

 

 

 

 

 

 

30”-

only

600W

CH B

 

 

 

 

ON

4– 16

2– 8

IN

(Mono)

 

 

 

 

Mono,70V,100V

 

Class 2 wiring

 

 

 

 

-18-15-12

 

 

 

 

-21

-9

 

 

 

 

-24

-6

 

 

 

 

-27

-3

 

Channel A

 

 

-32

 

 

 

 

-38

 

 

 

 

 

OFF

0dB

signal

protect

Stereo Mono

 

 

 

70V

 

 

 

 

 

100V

 

 

 

 

 

-18-15-12

clip

 

thermal

-21

-9

 

 

 

 

-24

-6

 

 

 

 

-27

-3

 

Channel b

 

 

-32

 

 

 

 

-38

 

 

 

 

 

OFF

0dB

 

 

A Division of

 

 

Rockford Corp.

 

®

Tempe, AZ 85281

 

G X 2 3 0 0

Made in the U.S.A.

 

300 W Stereo, 2– 8

 

For 70V, 100V, or Mono

600W Mono, 70V,100V

 

• Use CH B input

• Load across RED terminals

• Set load switches to one half load impedance

Attention: Utiliser un fusible de rechange de même type.

CAUTION: For continued protection from risk of fire, replace only with same type and rating of fuse.

250W

250V T7A 115V~

50-60Hz

1.Connect signal from source to CH B input.

2.Stereo/Biamp switch not active-(Stereo/Mono switch overrides this switch when in mono/70V/100V mode).

3.Move Stereo/Mono switch to MONO mode.

4.Set load switches (8/4/2) to 1/2 the actual load impedance. (16/8/4) i.e. for a 4speaker load,

select the 2setting for both CH A and CH B Load Switches

5.Connect appropriate speaker load 16/8/4across the red terminals of the 5-way binding posts.

6.CH B level control adjusts the mono output level. (1200W-GX2600, 600W-GX2300)

70V MONO MODE (GX2300/GX2600)

70V

 

 

 

 

 

 

 

 

 

100v 4

 

 

 

 

 

 

 

 

 

 

8

2

 

CH A

 

 

 

 

 

 

Load

 

 

Power

2300

 

 

 

 

 

 

 

 

 

 

70V

 

 

 

 

 

 

 

 

 

100v 4

 

 

 

 

 

 

 

 

 

 

8

2

 

CH B

 

 

 

 

 

 

100V

70V

 

 

 

 

 

100V

70V

 

GX2300

 

 

 

 

 

GX2600

 

 

 

 

HP

 

180˚–

Delay

 

 

 

Crossover LP

 

0˚–

 

 

 

 

Full

 

must

 

 

 

 

CD EQ +0

2

6

Phase choose

300W

 

 

 

 

 

one

 

2– 8

 

 

 

 

 

 

 

0”-

only

 

 

 

 

 

 

+10 dB

 

 

6”-

Audio GND

 

 

 

 

Freq

500Hz –

 

12”-

 

 

 

 

 

18”-

Chassis

Float

 

 

 

 

 

800Hz –

 

24”-

 

 

+

 

CH A

 

 

 

30”-

 

 

BIAMP STEREO

 

 

ON

 

 

IN

 

 

 

 

 

 

 

HP

 

180˚–

 

 

 

 

 

 

Crossover LP

 

0˚–

 

+

+

 

 

 

 

Full

 

Phase

 

 

 

CD EQ +0 2

6

 

Delay

 

 

 

 

+10 dB

 

 

0”-

 

 

 

 

 

 

 

 

 

6”-

must

 

 

 

 

 

Freq

500Hz –

 

12”-

choose

 

300W

 

 

 

 

18”-

 

 

 

 

 

800Hz –

 

24”-

one

 

 

 

 

 

 

 

 

30”-

only

600W

 

CH B

 

 

 

 

 

ON

4– 16

2– 8

 

IN

(Mono)

 

 

 

 

 

Mono,70V,100V

 

 

Class 2 wiring

70 Volt

Transformer

 

 

 

-18-15-12

 

 

 

-21

-9

 

 

 

-24

-6

 

 

 

-27

-3

 

Channel A

 

-32

 

 

 

-38

 

 

 

 

OFF

0dB

signal

protect

Stereo Mono

 

 

70V

 

 

 

 

100V

 

 

 

 

-18-15-12

clip

thermal

-21

-9

 

 

 

-24

-6

 

 

 

-27

-3

 

Channel b

 

-32

 

 

 

-38

 

 

 

 

OFF

0dB

 

A Division of

 

Rockford Corp.

®

Tempe, AZ 85281

GX 2 3 0 0 Made in the U.S.A. 300 W Stereo, 2– 8

For 70V, 100V, or Mono

600W Mono, 70V,100V

• Use CH B input

• Load across RED terminals

• Set load switches to one half load impedance

Attention: Utiliser un fusible de rechange de même type.

CAUTION: For continued protection from risk of fire, replace only with same type and rating of fuse.

250W

250V T7A 115V~

50-60Hz

70 Volt

etc.

Transformer

 

Parallel Array

1.Connect signal from source to CH B input.

2.Stereo/Biamp switch not active (Stereo/Mono switch overrides this switch when in mono/70V/100V mode).

3.Move Stereo/Mono switch to 70V mode.

4.Select 70V load, both channels.

5.Connect parallel array of 70V transformer-equipped speakers across the red terminals of the 5-way binding posts. (1200W–GX2600, 600W–GX2300)

6.CH B input sensitivity controls 70V mono output level. Amplifier will clip at 70Vrms level.

– 20 –