Operation

Flush the Equipment

Flush before changing colors, at the end of the day, before storing, and before repairing the equipment.

WARNING

Before flushing, be sure the entire system and all grounding pails are properly grounded. See page 8.

Flush with a fluid that is compatible with the fluid you are pumping and with the wetted parts of your system. Check with your fluid manufacturer or supplier for rec- ommended flushing fluids and flushing frequency. Always flush the pump before fluid dries on the displace- ment rod.

1. Relieve the pressure, page 12.

2.Remove the spray tip from the gun. See the gun manual.

3. Change the fluid source to solvent.

FLUSH

4.Hold a metal part of the gun firmly to the side of a grounded metal pail.

5.Start the pump. Always use the lowest possible fluid pressure when flushing.

6.Trigger the gun. Flush until clean solvent flows from the gun.

7. Relieve the pressure, page 12.

14

309463N

Page 14
Image 14
Haier 309463N important safety instructions Flush the Equipment