Haier AB212XCEAA operation manual Installation Procedure, Ring terminal connection method

Models: AB212XCEAA

1 28
Download 28 pages 37.9 Kb
Page 25
Image 25
1) Ring terminal connection method
Connection method for ring terminal

2) Straight terminal connection method Installation Procedure

! Warning

!

3) Clamping method of the connection wire The electric wiring work shall be conducted by qualified electricians according to the installation instructions. A separate power circuit shall be used. Insufficient power cord amperage or improper wiring will cause danger of electric shock or fire.

Manual background During wiring connection, the power cord shall be of the specified cable and reliably fastened so that external forces applied to the cable wouldnt transfer to the terminals. Improper connection or fastening will cause danger of heating, fire etc.The power cord must be fitted with a grounding wire. Manual background Grounding shall be made as specified. Unreliable grounding will cause electric shock. The grounding wire shall not be connected to the gas pipeline, water pipeline, thunder arrestor and telephone wire

! Caution

!

Manual background A current leakage breaker shall be installed, otherwise it electric shock would happen easily.

Manual background The connection method of power cord is "Y" type.

Manual background If the power cord is damaged, it must be replaced by the manufacturer or its service center or similar personnel to avoid risks. The power supply to the indoor unit shall be laid in complying with the operational instruction manual.

Manual background The electric wiring shall avoid contacting with the high temperature part of the piping so as to prevent the cable insulation melts and cause dangers.

Manual background After connected on the terminal block, the wires shall be bent to U form and then fastened with wire clip.

Manual background The control wiring and refrigerant piping may be laid and fastened together.

Manual background Before completion of vacuum pumping of the refrigerant pipe system, do not electrify the indoor unit.

Manual background The power cord of the indoor unit and connection wiring between indoor and outdoor units shall be laid out according to the operational instruction manual of the indoor unit.

Manual background The connection of the power cord shall comply with the local regulations.

Manual background The power supply wiring connection should meet the local regulation. Manual background After electric installation,power on them to do electric leakage test.

Wiring connection method : (the wiring diagram is attached inside the machine)

1) Ring terminal connection method

If there is a ring at the end of the connection wire, the wire connection method is as shown in the right figure. Remove the terminal screw and insert it through the ring at the connection wire end, then connect to the terminal board and fasten the screw.

2) Straight terminal connection method

If there isnt a ring at the end of the connection wire, the connection method shall be: loosen the terminal

screw, insert the connection wire end completely into the terminal board and fasten the screw. Pull the connection wire outwards slightly to confirm it is clamped tightly.

3) Clamping method of the connection wire

After wire connection is finished, the connection wire must be pressed tightly with wire clips, which shall apply to the outer sheath of the connection wire.

23

Page 25
Image 25
Haier AB212XCEAA Installation Procedure, Ring terminal connection method, Straight terminal connection method