Precaution for Installation

Please read these "Safety Precautions" first and then accurately execute the installation work.

Though the precautionary points indicated herein are divided under two headings, WARNING and CAUTION, those points which are related to the strong possibility of an installation done in error resulting in death or serious injury are listed in the WARNING section. However, there is also a possibility of serious consequences in relationship to the points listed in the CAUTION section as well. In either case, important safety related information is indicated, so by all means, properly observe all that is mentioned.

After completing the installation, along with confirming that no abnormalities were seen from the operation tests, please explain operating methods as well as maintenance methods to the user (customer) of this equipment, based on the owner's manual. Moreover, ask the customer to keep this sheet together with the owner's manual.

WARNING

This system should be applied to places as office, restaurant, residence and the like. Application to inferior environment such as engineering shop could cause equipment malfunction.

Please entrust installation to either the company which sold you the equipment or to a professional contractor. Defects from improper installations can be the cause of water leakage, electric shocks and fires.

Execute the installation accurately, based on following the installation manual. Again, improper installations can result in water leakage, electric shocks and fires.

When a large air-conditioning system is installed to a small room, it is necessary to have a prior planned countermeasure for the rare case of a refrigerant leakage, to prevent the exceeding of threshold concentration. In regards to preparing this countermeasure, consult with the company from which you perchased the equipment, and make the installation accordingly. In the rare event that a refrigerant leakage and exceeding of threshold concentration does occur, there is the danger of a resultant oxygen deficiency accident.

For installation, confirm that the installation site can sufficiently support heavy weight. When strength is insufficient, injury can result from a falling of the unit.

Execute the prescribed installation construction to prepare for earthquakes and the strong winds of typhoons and hurricanes, etc. Improper installations can result in accidents due to a violent falling over of the unit.

For electrical work, please see that a licensed electrician executes the work while following the safety standards related to electrical equipment, and local regulations as well as the installation instructions, and that only exclusive use circuits are used. Insufficient power source circuit capacity and defective installation execution can be the cause of electric shocks and fires.

Accurately connect wiring using the proper cable, and insure that the external force of the cable is not conducted to the terminal connection part, through properly securing it. Improper connection or securing can result in heat generation or fire.

Take care that wiring does not rise upward, and accurately install the lid/service panel. Its improper installation can also result in heat generation or fire.

When setting up or moving the location of the air conditioner, do not mix air etc. or anything other than the designated refrigerant (R410A) within the refrigeration cycle. Rupture and injury caused by abnormal high pressure can result from such mixing.

Always use accessory parts and authorized parts for installation construction. Using parts not authorized by this company can result in water leakage, electric shock, fire and refrigerant leakage.

CAUTION

Execute proper grounding. Do not connect the ground wire to a gas pipe, water pipe, lightning rod or a telephone ground wire. Improper placement of ground wires can result in electric shock.

The installation of an earth leakage breaker is necessary depending on the established location of the unit. Not installing an earth leakage breaker may result in electric shock.

Do not install the unit where there is a concern about leakage of combustible gas.

The rare event of leaked gas collecting around the unit could result in an outbreak of fire.

For the drain pipe, follow the installation manual to insure that it allows proper drainage and thermally insulate it to prevent condensation. Inadequate plumbing can result in water leakage and water damage to interior items.

20

Page 22
Image 22
Haier AD36NS1ERA, AD24MS1ERA, AD28NS1ERA, AD48NS1ERA operation manual Precaution for Installation

AD48NS1ERA, AD24MS1ERA, AD28NS1ERA, AD36NS1ERA specifications

The Haier AD36NS1ERA, AD28NS1ERA, AD24MS1ERA, and AD48NS1ERA are a series of air conditioners designed to provide optimal cooling solutions while ensuring energy efficiency and user comfort. Each model incorporates advanced technologies to meet varying space requirements and user preferences.

The Haier AD36NS1ERA is ideal for larger spaces, featuring a cooling capacity that ensures powerfully efficient temperature control. This unit utilizes inverter technology, allowing for variable speed operation. This means it can adjust the cooling output based on the ambient temperature, resulting in significant energy savings while maintaining consistent comfort. It is equipped with features such as a dehumidification mode, which helps to reduce excess moisture in the air, promoting a healthier indoor environment.

On the other hand, the Haier AD28NS1ERA is a versatile choice for medium-sized rooms. It shares the inverter technology of its larger counterpart, providing energy-efficient performance without sacrificing cooling power. This model also includes a user-friendly remote control for easy operation, allowing users to adjust settings from the comfort of their seating area. Additionally, it comes with a stylish design that fits seamlessly into modern home aesthetics.

The Haier AD24MS1ERA is designed for compact spaces, making it an excellent option for smaller rooms or apartments. Despite its size, it does not compromise on performance. The unit also features eco-friendly refrigerants that contribute to a lower environmental impact. Its compact design and quiet operation make it a perfect fit for bedrooms or study areas where noise can be a concern.

Lastly, the Haier AD48NS1ERA stands out with its powerful cooling capacity, ideal for larger residential or commercial spaces. It features multi-functional capabilities, including cooling, heating, and fan modes, providing year-round comfort. The advanced filtration system included in this model helps to purify the air by trapping dust and allergens, ensuring that the environment remains clean and healthy.

In summary, Haier's AD series air conditioners, including the AD36NS1ERA, AD28NS1ERA, AD24MS1ERA, and AD48NS1ERA, offer a variety of features tailored to meet different cooling needs. With technologies such as inverter operation, user-friendly controls, and efficient air filtration systems, these models stand out for their performance and environmental consciousness. Whether for a compact room or a spacious area, Haier's offerings cater to diverse preferences, ensuring a comfortable living experience year-round.