Haier AD36NAMBEA(ECO) For Preparation of HeatingHot Keep, Warming Operation, Defrosting operation

Models: AD182AMBEA(ECO) AD242AMBEA(ECO) AD28NAMBEA(ECO) AD36NAMBEA(ECO) AD42NAMBEA(ECO)

1 19
Download 19 pages 16.73 Kb
Page 11
Image 11
 For Preparation of Heating("Hot Keep")

"HOT KEEP"is operated in the following cases. For Preparation of Heating("Hot Keep")

"HOT KEEP"is operated in the following cases.

When heating is started:

In order to prevent blowing out of cool wind, the indoor unit fan stopped according to the room temperature which heating operation is started. Wait for approx. 2 to 3 minute, and the operation will be automatically changed to the ordinary heating mode.

Defrosting operation (in the heating mode):

When it is liable to frost. the heating operation is stopped automatically for 5 to 12 minutes once per approx. one hour, and defrosting is operated. After defrosting is completed, operation mode is automatically changed to ordinary heating operation.

When heating is started: When the room thermostat is actuated:

When room temperature increases and room temperature controller actu- ates, the fan speed is automatically changed to stop under low temperature condition of indoor heat exchanger. When room temperature decreases, air conditioner automatically changes over to ordinary heating operation.

Defrosting operation (in the heating mode): WARMING OPERATION

 When the room thermostat is actuated: Heat pump type warming

With the heat pump type warming, the mechanism of heat pump that concentrate heat of outdoor air with the help of refrigerant to warm the indoor space, is utilized.

 WARMING OPERATION Defrosting operation

When a room is warmed with a heat pump type air conditioner, frost accumulates on the heat ex- changer of outdoor unit along with the drop of indoor temperature. Since the accumulated frost re- duces the effect of warming, it is necessery to automatically switch the operation to the defrosting mode. During the defrosting operation, heating operation is interrupted.

 Heat pump type warming Atmospheric temperature and warming capacity

Warming capacity of heat pump type air conditioner decreases along with the drop of outdoor temperature.

When the warming capacity is not sufficient, it is recommended to use another

heating implement.

 Defrosting operation Period of warm-upSince the heat pump type air conditioner employs a method to circulate warm winds to warm the entire space of a room, it takes time before the room tem- perature rises.

It is recommendable to start the operation a little earlier in a very cold morning.

10

Page 11
Image 11
Haier AD36NAMBEA(ECO) For Preparation of HeatingHot Keep, Warming Operation, When heating is started, Defrosting operation