Parameters
Rated voltage: 220V~,50Hz | Dimension: (See to Figure 1) |
Power: 1500W | Weight: (See to Figure 1) |
Rated pressure: 0.65 / 0.75MPa | Volume: (See to Figure 1) |
Waterproof grade: IPX 4 ( ) | Tap water pressure: no less than 0.05MPa |
Dimensions
(Figure 1)
Front view |
| Cutaway view | Bottom view |
a1 |
| d1 |
|
|
| ||
|
|
| |
|
|
|
|
Operation Instructions
For the first use after installation, due to there's no water within the tank, first the city water inlet valve and mixing valve must be opened. Close the mixing valve when water flows out continuously from the showerhead or other outlets (the tank is full). Check connections are free of water leakage, and insert the power plug.
Turn the knob to set your desired water heating temperature, which can be stepless changed between cold water inlet temperature and 75 . In heating mode, heating lamp is lighted on. Normally the knob shall be positioned at highest temperature. This machine has a thermostat function, which automatically switches off the water heater when temperature reaches the setting value, and switch on again when water temperature decreases to certain value.
City water pressure 0.75 MPa will cause much water flowing out from safety valve
E
b1
D
A B
C
f1
E
C1 |
e1
pressure relief vent. This is due to too high water pressure. Please ask
Attentions in Operation
Model |
| Volume | Net | a1 | b1 | c1 | d1 | e1 | f1 |
| weight | ||||||||
FCD- |
| 40L | 18.5kg | 673mm | 391mm | 100mm | 220mm | 365mm 197mm | |
JTHA40- | (E) | ||||||||
|
|
|
|
|
|
|
|
|
|
FCD- |
| 50L | 20kg | 702 mm | 444 mm | 100 mm | 235 mm | 390 mm 197 mm | |
JTHA50- | (E) | ||||||||
FCD- |
| 60L | 22.8kg | 802 mm | 444 mm | 100 mm | 335 mm | 390 mm 197mm | |
JTHA60- | (E) | ||||||||
|
|
|
|
|
|
|
|
|
|
A Hot water outlet B Cold water inlet C Heating element D Enamel tank
E
1. | To avoid causing machine troubles, do not connect power before tank is full of water. |
2. | Adjust a suitable temperature before use, for water temperature above 50 may burn |
| your skin. |
3. | This product is closed water heater, which can supply hot water through pipe |
| connection to several points like bathroom (bathtub, washbasin, showerhead) and |
| kitchen. |
4. | Heating adjustment can be made flexibly all year round adapting to climate changes. In |
Remarks:the permitted error limit of above parameters is 10%.
Electric Circuit Diagram
valve to hot water range, and move up safety valve handle to drain the tank. To avoid |
injury, before next use, it is suggested to first open hot water valve before switching on |
the water heater, exhausting gas possibly retained in the pipeline. In this case, no |
smoke or fire is permitted near the open valve. Carefully check and confirm all parts are |
in good condition. |
L:Brown wire
N:Blue wire
MT: High temperature limiter
BT: Thermostat | L | ||
HL:Heating indicator |
|
|
|
|
|
| |
EH:Heating element |
|
|
|
E:Yellow/green wire | N | ||
|
|
|
|
MT
E
BT
HL
EH
E
5. Provided hot water quantity can meet use demand, temperature setting shall be |
possibly low. It can minimize heat dissipation, |
sedimentation, ensuring a longer service life. |
6. Regularly ask servicemen to make safety inspection, remove sediment on heating |
elements, and check consumption of anode bar. Too much consumed anode bar shall |
be replaced. |