Setting Environment

Setting Environment

Do not set it at place where is too cold and

Do not set at outdoor places.

may freeze.

Do not use as floorstanding appliance.

Please mount it to firm and reliable wall.

² »Ò ª° ײ °Ó ÚÎ Þ· Ũ ËÅ ®µ ĵ Ø· ½

Installation

Installation must be made by installers of or designated by our company after-service department. The water heatershall be wall-mounted.

Before installation, make sure water heater rear wires are fit firmly. Determine an installation location. Make four holes Connection and use of safety valve: 12mm, 65 mm deep in the wall with an impact drill according to installating dimension. Insert fixexpansion hooks and expansion bolts in corresponding wall holes. Lift the water heater. Insert wall rack onto the hooks and bolts. Fit flat washers, rear wires and nuts in turn onto the bolts (see Figure 2). Tighten the nuts and check them firm. Install accessories such as safety valve, drain hose as shown in Figure 3. Use sealing compound to prevent water leakage.

To facilitate installation and removal, it is suggested a G 1/2" movable nut is fitted at appropriate locations on inlet and outlet pipes respectively. Find water supply location. Connect inlet pipe, outlet pipe and city water pipe respectively to the use point.

The hot water pipe shall not be too long to reduce the heat losses.

Please reserve some space in installation for the future maintenance.

 

In case connecting water heater with water drain

Do not install to places without sewer.

hose, connect the drain hose to the inlet of the

 

Hot water outlet valve

 

Hot

 

water

 

outlet

 

Cold water inlet

Cold water

Shower head

outlet valve

Mixing valve

 

Safety valve

sewer to avoid polluting by splashing.

The original pipeline of the water heater is an organic part of "Safe Care". Do not remove it by yourself. Otherwise we will not take responsibility for the injure and loss caused by the safety trouble occurred therefrom.

Description of the Symbols

Never do that

Be sure to act as per instructions

5

(Figure 2)(Figure 3) for reference in installation only

Connection and use of safety valve:

The safety valve should be connected to the cold water inlet pipe. Please check carefully if the direction is correct after installation. The correct direction of installation is that the arrowhead on the safety valve should point to the water heater.

Please connect the drain hose to the safety valve. Connect one end of the hose to the safety valve vent and the other end to the sewage drain. The hose can be cut short or extended as necessary. The hose shall be installed as inclined downward.(see to Figure 4)