Installation
The water may drip from the discharge pipe of the pressure relied device and that this pipe must be installed in a continuously downward direction and in a
The pressure relief device is to be operated regularly to remove lime deposits and to verify that it is not blocked.
Connect to drain hose
Safety Precautions
22 | 0V | Hz | |
50 | |||
|
|
Check if the ammeter and the diameter of the wires are in |
|
accordance with the rated current of the water heater. If |
|
necessary please have it checked by experienced | The water heater adopts power supply of 220V~ ,50Hz. |
electrician. |
|
| £Ð | ¡ |
| л |
| |
|
|
| |
² |
|
|
|
Attentions in Installation
During installation, adequate space must be reserved for future maintenance and repair. If the water heater is installed within decoration boards, the right board shall be removable to facilitate removing the plastic cover during maintenance.
City water inlet pressure shall not be less than 0.05 Mpa.
Electric water heater shall be installed indoors with ambient temperature above 0 . The pipes shall be collectively laid. Hot water outlet shall not be too far from use points. In case farer than 8 m, hot water pipe shall have a thermal insulation to minimize heat loss.
The mounting wall shall be firm and reliable to support twice the weight of water heater full of water.
Electric water heater shall be located in a place easy for use, maintenance and with a floor drainer. In case the tank or pipes leak, nearby or lower facilities shall not be damaged. The installation location shall avoid being above toilet bowl, bathtub, washbasin or doorframe, where will cause a suppressed or unsafe feeling to users.
Power socket for water heater shall be in a dry place free of water splash. (splash- proof box is preferred)
Do not confuse inlet and outlet water pipes. Safety valve shall be installed at designated position with no random modification.
Be sure to use independent receptacle and earth it reliably. | Set | the receptacle of |
| the water heater at dry | ||||||
position away from water spraying. Do not insert | ||||||||||
The receptacle shall comply with the stipulation of | ||||||||||
and |
| pull the power |
| plug | with wet hands . | |||||
national standard. |
|
| ||||||||
|
|
|
|
|
|
|
|
| ||
|
|
| ¡ | ¡ | ² |
|
| ² | ||
|
|
| Ô´ |
|
|
|
| »¿ | ||
|
|
| ÚÏÔ´ |
| »¿ |
|
| |||
|
|
| ÓÃ |
|
| ÉÒ |
| ÒÉ | ||
|
|
| Ó´ ÏÚ |
|
|
| Ô | |||
|
| ¢¼ | ÓÃ |
|
|
|
| Ô | ||
| Á | ´Ó |
|
|
|
| ||||
| ¼¢ |
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
| ||
| Á |
|
|
|
|
|
|
|
| |
After installation, be sure to fill the heater completely with | In opening and closing the water valve, do not point | |||||||||
water before switching on the power in the first usage. | the shower head to human body. Otherwise it may | |||||||||
Children must take bath under the supervision of adult. | hurt by the spraying hot water. | |||||||||
C |
|
|
|
|
|
|
|
|
| |
In winter of cold area, if the heater is idle for a long | In case the power cord of the water heater is | |||||||||
period, please pull the handle of safety valve to discharge | damaged, be sure to have it replaced by after service | |||||||||
the water. Otherwise it may freeze inside the water heater | technicians with special cord offered by the | |||||||||
and cause damages. | manufacturer. |
|
|
|
|
|
The product adopts the patent "Safe Care" technology of our company. As long as adopting civil power supply, even if the earthing wire is electrified by mistake, the "Safe Care" technology still can block the dangerous electricity, and ensure your personal safety. But if you find perceptible current, please pull off the power plug and contact local after service department for maintenance. Do not disassemble by yourself.
Description of the Symbols
Never do that
Be sure to act as per instructions
4